DO NOT use alcohol as a germicide
because it may deteriorate rubber parts.
Depending on the cleaning policy adopted,
either a designated person or the user
should clean the respirator after each use.
Non-sudsing Confidence Plus® Cleaning
Solution (P/N 10009971) from MSA is rec-
ommended. It is a germicidal cleaner that
cleans and disinfects in one operation. It
retains its germicidal efficiency in hard water
to inhibit the growth of bacteria. It will not
deteriorate rubber, plastic, glass, or metal
parts. Refer to the label for use instructions.
A solution as effective as Confidence Plus
Cleaning Solution and compatible with MSA
respirator components may be substituted.
ANSI suggests that users be trained in the
cleaning procedure.
Be careful not to breathe or touch the
contaminant in handling the respirator or
its parts. If necessary, use equipment
disposal to protect you from the specific
contaminant. Failure to follow this warn-
ing can result in serious personal injury
or death.
1. Preparing Solution
a. Follow the instructions with the
Confidence Plus Cleaning Solution.
b. If the Confidence Plus Cleaning
Solution is not used, wash in a mild
cleaning solution, rinse thoroughly,
and submerge in a germicide solution
for the manufacturer's recommended
time.
2. Clean and Disinfect the Facepiece
a. Remove the canister/cartridge(s) from
the facepiece.
b. Thoroughly wash the facepiece (and
nose cup) in the cleaning solution. A
soft brush or sponge can be used to
clean the soiled facepiece. Be sure to
include cleaning the exhalation valve
and seat.
c. Rinse the facepiece and components
in clean, warm (110°F), water (prefer-
ably running and drained).
If not rinsed thoroughly, cleaning agent
residue may irritate the wearer's skin.
d. Allow the facepiece to air dry. Do not
dry the parts by placing them near a
heater or in direct sunlight. The rubber
will deteriorate.
e. Operate the exhalation valve by hand
to be sure it works properly.
f. Harness (straps and buckles)
g. The facepiece and components
should be air-dried or hand-dried with
a clean lint-free cloth.
DO NOT force-dry the parts by placing
them in a heater or in direct sunlight. The
rubber will deteriorate. When facepiece is
thoroughly dried, store the facepiece in
the clam shell in which it was shipped.
CLEANING AND DISINFECTING
LVG 322 (L)
Rev. 1
3
- 10050775
23