For Ultra-Twin Adapter (P/N 803622)
1. Check to ensure the spider gasket is in
place in the inlet assembly.
DO NOT use unless the spider gasket is
in place. An air-tight seal cannot be
achieved without the spider gasket. Use
without the spider gasket can result in
the user suffering serious respirator
injury or death.
2. Remove the adapter from bag and posi-
tion in the inlet of the facepiece.
3. Hand-tighten the plastic nut on the
adapter making sure the mail portion of
the adapter seals against the spider gas-
ket in the facepiece inlet.
4. If using the Duo-Twin plug as described
in the following section.
5. Remove the replacement cartridges from
the storage bags and insert them into
the threaded receptacles making sure
the gaskets are in place in the recepta-
cles.
6. Carefully hand-tighten the cartridges to
prevent damage to threads. To ensure a
good seal against the gaskets, tighten
each cartridge by gripping as much of
the circumference of the receptacle as
possible and then slowly turn the car-
tridge until tight.
7. If applicable, place a new filter in each
filter cover. Never load filters into the
receptacles.
FOR USE WITH C420 POWERED AIR
PURIFYING RESPIRATOR (PAPR)
Ultra Elite Facepieces are approved for use
with C420 PAPR motor blower. Refer to the
NIOSH approval label for approved configu-
rations. In addition to this manual, the C420
manual (P/N 10072074) must be carefully
read and followed by all persons who have,
or will have, the responsibility for using or
servicing the respirator.
PREPARING THE RESPIRATOR FOR USE
LVG 322 (L) Rev. 13 - 10050775
16