This respirator/filter provides
LIMITED protection. It may help
reduce exposure to airborne bio-
logical agents, including H1N1
(swine) flu virus, avian (bird) flu
virus, other types of influenza,
SARS, or other bacterial or viral
biological agents and help reduce
the risk for influenza infection
during a pandemic, but will NOT
eliminate the risk of exposure,
infection, illness, or death.

This respirator/filter is certified by
NIOSH to comply with the
requirements specified for the
designated filter efficiency level;
however, appropriate authorities
have NOT established a safe level
of exposure to biological agents.
Therefore, the respirator may
NOT prevent transmission of
influenza virus.

Refer to the Centers for Disease
Control and Prevention (CDC) at
www.cdc.gov for guidance on the
use of respirators to help
decrease exposure to H1N1 virus
or other airborne biological
agents in community, home, and
occupational settings. The CDC
recommends fit testing, medical
evaluations, and training for opti-
mal effectiveness when a respira-
tor is used in a non-occupational
setting. Neglecting these
preparatory measures may cause
an unsafe condition. Respirators
used in an occupational setting
MUST be used in accordance
with a complete respiratory pro-

tection program as required by
OSHA, which includes proper
selection, training, fit-testing, and
fit-checking. Detailed information
on a respiratory protection pro-
gram is available by contacting
OSHA or visiting www.osha.gov.

Do NOT remove respirator in con-
taminated areas. The outer sur-
face of the respirator MUST be
treated as if it is contaminated at
all times. Tight-fitting safety gog-
gles, or a full-facepiece respira-
tor, may further help prevent
transmission of influenza virus.

The CDC recommends frequent
hand washing and wearing gloves
to help prevent transmission of
disease due to exposure to sur-
faces where contaminants may
be present, and also immediately
following removal of the respira-
tor.

Do NOT reuse or share mainte-
nance-free respirators. ALWAYS
clean cartridge-style respirators
before reuse in accordance with
the instructions provided.

This respirator/filter is NOT for
use by (a) children, or (b) people
with a medical condition that may
be adversely affected by using it.

Failure to follow all warnings and
instructions can result in serious per-
sonal injury or death.

5

Visit: www.thesafetyequipmentstore.com Or Email: [email protected] for Sales & Service.

Содержание OptimAir Mask-Mounted PAPR

Страница 1: ...for NIOSH Approval Information P N 818105 This manual including the warnings and cautions inside must be read and followed carefully by all persons who use or maintain this product including those who...

Страница 2: ...e modify add or omit parts Use only exact replace ment parts in the configuration specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for informa tion on use and ma...

Страница 3: ...must be taken so that the respirator is not worn in atmospheres that may be harmful to the device 6 Do not alter modify or substitute any components without the approval of the manufacturer Such alter...

Страница 4: ...in conjunction with proper chemi cal or particulate cartridges for protection against specific con taminants 3 Do not use when concentrations of contaminants are unknown or immediately dangerous to li...

Страница 5: ...y measures may cause an unsafe condition Respirators used in an occupational setting MUST be used in accordance with a complete respiratory pro tection program as required by OSHA which includes prope...

Страница 6: ...TAL 114 L Rev 4 10090982 NOTES 6 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Страница 7: ...ak occurs air will flow from inside the facepiece to the outside air This is referred to as positive pressure Air flow also provides wearer comfort The rechargeable NiMH battery pack supplies 4 8 volt...

Страница 8: ...blishes the following information to determine the TLV of a mixture First determine the total concentration of the chemical mixture CMixture from the individual contaminant con centrations C1 C2 C3 us...

Страница 9: ...erates from the compro mised battery pack the battery pack must be replaced The motor blower housing can be damaged by impact The blower impeller can be loosened or the motor shaft can be bent If the...

Страница 10: ...The charger uses one LED When the battery is charging the LED will be Red When the LED is Green the bat tery is fully charged The battery can stay connected to the charger until it is needed If the L...

Страница 11: ...into the facepiece 3 If attached unthread the filter from the motor blower assembly 4 Check that there is a gasket in the motor blower housing The gasket is neces sary so that the filter and motor blo...

Страница 12: ...TAL 114 L Rev 4 10090982 NOTES 12 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Страница 13: ...serious personal injury or death DONNING THE SUPPORT BELT AND BATTERY PACK 1 Thread the belt through the belt loops on the battery pack 2 Don the support belt The battery pack may be worn on either s...

Страница 14: ...e top straps a Remove the strap from the fas tener button by pulling the loose end of the strap away from the fastener button b Move the slide away from the lens ring to allow the strap to slide throu...

Страница 15: ...or other distress occurs you taste or smell the contaminant you experience eye nose or throat irritation If you bump or impact the car tridges leave area immediately and check the security of the car...

Страница 16: ...s respiratory protection with the motor blower off because all air is still drawn through the filter However breathing resistance will be greater than when the motor blower is supplying air to the fac...

Страница 17: ...The filter is not designed to be cleaned and reused Do not try to clean the filter You may damage the inside of the filter and eliminate res piratory protection resulting in seri ous respiratory injur...

Страница 18: ...e respirator or its parts Use equipment designed to protect you from the specific contaminant Failure to follow this warning can result in serous personal injury or death 1 Preparing the cleaner a Fol...

Страница 19: ...not be used as a germicide because it may deterio rate the rubber 5 Use a damp cloth or sponge satu rated with Confidence Plus clean ing solution or an equivalent solu tion to wipe the motor blower a...

Страница 20: ...ures will decrease capacity and operating time will be reduced The other OptimAir Mask Mounted PAPR components can be stored at temperatures of 0 F to 120 F 20 Visit www thesafetyequipmentstore com Or...

Страница 21: ...t self discharge Amber Charge Pending Battery Temperature is outside the charge range If the battery is too hot charge will not begin until temperature falls If temperature is too low charger will tri...

Страница 22: ...eter to measure voltage 2 Turn the switch on the battery pack to the OFF position 3 Place the positive probe on pin 2 and the negative lead on to pin 3 4 The voltage should read 0 Volts 5 Turn the swi...

Страница 23: ...arge the battery until a full charge is achieved Testing the Flow of the Motor Blower 1 Assemble the motor blower to the battery pack 2 Attach the motor blower to the flow meter per the supplied instr...

Страница 24: ...Successful Charge Green LED Charge Failure Red Flashing LED Replace Charger Replace Original Battery Pack Mtr Blower Resistance Test Mtr Blower Flow Test Fail Fail Fail Fail Fail Replace Mtr Blower Ch...

Страница 25: ...piece seal 3 Stretch nosecup over Inhalation Valve Housing ensuring notch of nosecup is over tab of inhalation valve housing 4 Stretch nosecup around lip on inhalation valve housing ensuring nosecup i...

Страница 26: ...0090982 ACCESSORIES PARTS Confidence Plus Cleaner P N 100009971 Flow Check Meter P N 487995 and Adapter P N 491046 26 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com...

Страница 27: ...TAL 114 L Rev 4 10090982 27 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Страница 28: ...82 28 804805 804804 804820 10116528 19a Door Component Housing ClearCommand 804831 495188 495189 10051290 805011 804810 a Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore...

Страница 29: ...TAL 114 L Rev 4 10090982 29 20 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Страница 30: ...TAL 114 L Rev 4 10090982 30 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Страница 31: ...TAL 114 L Rev 4 10090982 NOTES 31 Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Страница 32: ...Visit www thesafetyequipmentstore com Or Email besafe thesafetyequipmentstore com for Sales Service...

Отзывы: