background image

QUICK-FILL SYSTEM OPERATION

TRANSFILLING BETWEEN SCBA FROM MSA
(EMERGENCY BREATHING SYSTEM)

Note:

The SCBA with the higher pressure reading is the

donor. The SCBA with the lower pressure is the receiver.
Transfilling between users of SCBA should be performed
only during life-threatening emergencies or simulated
training exercises. Both donor and receiver must return to
fresh air immediately following the procedure.

DO NOT transfill if the donor's audible alarm is ringing
or NightFighter Heads-Up Display System/ ICM Unit
Gauge are flashing. Failure to follow this warning may
result in shorter escape time to return to fresh air,
causing serious personal injury or death.

The audible alarm begins ringing and NightFighter Heads-
Up Display System begins flashing to indicate that the
pressure in the cylinder has been reduced to 25% of its
rated working pressure. Remaining service time must be
used for escape to fresh air. If the

donor's

audible alarm

begins ringing or NightFighter Heads-Up Display
System/ICM Unit Gauge begins flashing during transfilling,
the

donor

should disconnect and preserve his escape

time.

1. If the donor's alarm is not ringing or NightFighter

Heads-Up Display System/ICM Unit Gauge are not
flashing and you have sufficient air to transfill air to a
receiver, (greater than 1000psig for Low Pressure
SCBA and greater than 2000psig for High Pressure
SCBA), follow these steps.

a. Remove the 3 foot emergency transfill hose from its

protective pouch.

b. Remove the rubber dust cover from both female fit-

tings on the Quick-Fill System hose assembly.

c. Remove the rubber dust cover from the male Quick-

Fill System fitting.

d. Push the female fittings on to the male fittings until

they click in place. Pull on the hose to be sure it
snapped in place.

If serious leakage is noticed from either of the two
female fittings, or anywhere along the hose, discon-
nect the female fittings and return to fresh air immedi-
ately. Failure to follow this warning may result in seri-
ous personal injury or death.

e. After approximately 30-60 seconds, pressure

between the SCBA cylinders will be equal.

f. Disconnect the Quick-Fill System hose from the

SCBA by pulling the gray sleeve back on both ends.
A hiss or pop may be heard as the fittings separate
and the high pressure air is sealed off.

g. Immediately install the dust cover on the Quick-Fill

System male fitting. The dust cover prevents dirt,
water, and debris from entering the fitting and acts
as a redundant seal.

QUICK-FILL SYSTEM EMERGENCY OPERATIONS

1. If the dust cover will not stay on the male fitting

because air is leaking:

a. Immediately reconnect the Quick-Fill System hose

to seal off the leak and return to fresh air.

b. If you cannot reconnect the hose, reach behind and

close the cylinder valve. Air pressure in the regulator
will drop and the leak will slow down.

c. Quickly replace the protective dust cap on the male

fitting. This will form a redundant seal.

d. Open the cylinder valve and return to fresh air

immediately.

2. Preparing the Quick-Fill System for Storage:

a. Press in on the center of the quick-disconnect dust

cap to release any pressure in the Quick-Fill System
hose.

b. Roll up the hose and place it in its protective pouch.

Note:

Only persons trained in MSA Maintenance are

authorized to repair or disassemble the Quick-Fill System.
If repairs are required, contact your nearest MSA office.
Call 1-800-MSA-2222.

19

TAL 709 (L) Rev. 4 - 10058881

Содержание ICM Tx

Страница 1: ...Display System which integrates with the SCBA These instructions in addition to the instructions supplied with the SCBA must be carefully read and followed by all persons who use or maintain this prod...

Страница 2: ...epiece Note The NightFighter Heads Up Display can only be used with an Ultra Elite Facepiece 2 The NightFighter Heads Up Display consists of three 3 separate assemblies Bracket assembly attached to an...

Страница 3: ...nation of batteries from dif ferent manufacturers will affect the performance of unit and void the Intrinsic Safety Approval Intrinsically Safe Rating The NightFighter Heads Up Display System and ICM...

Страница 4: ...4 TAL 709 L Rev 4 10058881 NOTES...

Страница 5: ...he facepiece which displays the air cylinder pressure in one quarter cylinder increments by an LED light pattern See chart 1 Assembly of Receiver to Facepiece Bracket With the facepiece laying on its...

Страница 6: ...6 TAL 709 L Rev 4 10058881 NOTES...

Страница 7: ...m the unit o The center lighted ALARM button green red acti vates the full alarm mode with or without air pres sure o The top MODE button green will refresh the receiv er display set the receiver to c...

Страница 8: ...8 TAL 709 L Rev 4 10058881 NOTES...

Страница 9: ...Pressure Full Alarm with or without Pressure Deactivation of Full Alarm Deactivation of PreAlarm with Shake or move Unit Low Battery Thermal Alarm Activation see Thermal Alarm Activation Curve Redunda...

Страница 10: ...trinsic Safety Approval is void Failure to follow this warning can result in serious personal injury or death Before using the ID tag inspect for damage or cracks in the case If damage is found discar...

Страница 11: ...he bypass valve on the second stage regulator to bleed off pressure until the ICM Tx Unit pressure reading drops below the following values a 530psig approximately 2216psi system b 750psig approximate...

Страница 12: ...NOTES 12 TAL 709 L Rev 4 10058881...

Страница 13: ...injury or death Actual time remaining may be less than the calculated time displayed Increases in breathing rate may reduce remaining time more than expected Use time indica tor as general guide only...

Страница 14: ...sure to tighten the battery cover screws enough to provide adequate compression on the battery cover gasket to prevent dirt and moisture from entering the battery compart ment A torque of 6 in lbs is...

Страница 15: ...for missing screws or loose covers c Check for signs of leaking covers or water retention in the case d Check rubber cover for damage e Check for damaged or missing buttons on the unit f Check for any...

Страница 16: ...cover 4 Before replacing the battery cover be sure that the rubber cover on the ICM Tx Unit is properly engaged with the plastic housing The rubber cover has barbs that hold it firmly against the plas...

Страница 17: ...transfilling hose assembly or fittings other than those supplied by MSA specifically for the Quick Fill System Use of any other transfilling hose assembly and or fitting may result in serious personal...

Страница 18: ...System hose to the SCBA c Remove the rubber dust cap from the male inlet fit ting on the SCBA Be sure that the cylinder valve is fully opened d Remove the rubber dust cap from the female fitting on th...

Страница 19: ...he male Quick Fill System fitting d Push the female fittings on to the male fittings until they click in place Pull on the hose to be sure it snapped in place If serious leakage is noticed from either...

Страница 20: ...NOTES 20 TAL 709 L Rev 4 10058881...

Страница 21: ...emblies 485331 802687 802688 802689 802690 and 48332 for filling cylinders in IDLH atmospheres DO NOT Transfill be a Donor using a 3000psi URC Assembly The 3000psi URC Assembly has a check valve that...

Страница 22: ...either female fitting or along the hose depressurize the hose and correct the prob lem Such leakage can result in increased fill time 2 To attach the Quick Fill System hose to the URC Assembly a Remo...

Страница 23: ...c Quickly replace the protective dust cap on the URC Assembly male regulator fitting This will form a redundant seal d Open the cylinder valve and return to fresh air immediately The dust cover preven...

Страница 24: ...eration and instructions manual PN 10023638 for additional war ranty information For a copy of the complete warranty or for information on submitting a warranty claim write to MSA Customer Service Dep...

Отзывы: