WARRANTY

WARRANTY INFORMATION

The ICM Tx Unit is warranted to be free from mechanical
defects or faulty workmanship for two (2) years from first
use or eighteen (18) months from the date code, whichev-
er occurs first, provided it is maintained and used in
accordance with MSA’s instructions and/or recommenda-
tions. Refer to MMR Air Mask with Firehawk operation
and instructions manual PN 10023638 for additional war-
ranty information.

For a copy of the complete warranty

or for information on submitting a warranty claim, write to
MSA, Customer Service Department, P.O. Box 426,
Pittsburgh, PA 15230-0426 or call 1-800-MSA-2222.

For further information or training instructions contact
your MSA representative or distributor.

For questions or comments regarding the certification of
this product, contact Safety Equipment Institute:
1307 Dolley Madison Blvd.
Suite 3A
McLean, VA 22101

24

TAL 709 (L) Rev. 4 - 10058881

Содержание ICM Tx

Страница 1: ...Display System which integrates with the SCBA These instructions in addition to the instructions supplied with the SCBA must be carefully read and followed by all persons who use or maintain this prod...

Страница 2: ...epiece Note The NightFighter Heads Up Display can only be used with an Ultra Elite Facepiece 2 The NightFighter Heads Up Display consists of three 3 separate assemblies Bracket assembly attached to an...

Страница 3: ...nation of batteries from dif ferent manufacturers will affect the performance of unit and void the Intrinsic Safety Approval Intrinsically Safe Rating The NightFighter Heads Up Display System and ICM...

Страница 4: ...4 TAL 709 L Rev 4 10058881 NOTES...

Страница 5: ...he facepiece which displays the air cylinder pressure in one quarter cylinder increments by an LED light pattern See chart 1 Assembly of Receiver to Facepiece Bracket With the facepiece laying on its...

Страница 6: ...6 TAL 709 L Rev 4 10058881 NOTES...

Страница 7: ...m the unit o The center lighted ALARM button green red acti vates the full alarm mode with or without air pres sure o The top MODE button green will refresh the receiv er display set the receiver to c...

Страница 8: ...8 TAL 709 L Rev 4 10058881 NOTES...

Страница 9: ...Pressure Full Alarm with or without Pressure Deactivation of Full Alarm Deactivation of PreAlarm with Shake or move Unit Low Battery Thermal Alarm Activation see Thermal Alarm Activation Curve Redunda...

Страница 10: ...trinsic Safety Approval is void Failure to follow this warning can result in serious personal injury or death Before using the ID tag inspect for damage or cracks in the case If damage is found discar...

Страница 11: ...he bypass valve on the second stage regulator to bleed off pressure until the ICM Tx Unit pressure reading drops below the following values a 530psig approximately 2216psi system b 750psig approximate...

Страница 12: ...NOTES 12 TAL 709 L Rev 4 10058881...

Страница 13: ...injury or death Actual time remaining may be less than the calculated time displayed Increases in breathing rate may reduce remaining time more than expected Use time indica tor as general guide only...

Страница 14: ...sure to tighten the battery cover screws enough to provide adequate compression on the battery cover gasket to prevent dirt and moisture from entering the battery compart ment A torque of 6 in lbs is...

Страница 15: ...for missing screws or loose covers c Check for signs of leaking covers or water retention in the case d Check rubber cover for damage e Check for damaged or missing buttons on the unit f Check for any...

Страница 16: ...cover 4 Before replacing the battery cover be sure that the rubber cover on the ICM Tx Unit is properly engaged with the plastic housing The rubber cover has barbs that hold it firmly against the plas...

Страница 17: ...transfilling hose assembly or fittings other than those supplied by MSA specifically for the Quick Fill System Use of any other transfilling hose assembly and or fitting may result in serious personal...

Страница 18: ...System hose to the SCBA c Remove the rubber dust cap from the male inlet fit ting on the SCBA Be sure that the cylinder valve is fully opened d Remove the rubber dust cap from the female fitting on th...

Страница 19: ...he male Quick Fill System fitting d Push the female fittings on to the male fittings until they click in place Pull on the hose to be sure it snapped in place If serious leakage is noticed from either...

Страница 20: ...NOTES 20 TAL 709 L Rev 4 10058881...

Страница 21: ...emblies 485331 802687 802688 802689 802690 and 48332 for filling cylinders in IDLH atmospheres DO NOT Transfill be a Donor using a 3000psi URC Assembly The 3000psi URC Assembly has a check valve that...

Страница 22: ...either female fitting or along the hose depressurize the hose and correct the prob lem Such leakage can result in increased fill time 2 To attach the Quick Fill System hose to the URC Assembly a Remo...

Страница 23: ...c Quickly replace the protective dust cap on the URC Assembly male regulator fitting This will form a redundant seal d Open the cylinder valve and return to fresh air immediately The dust cover preven...

Страница 24: ...eration and instructions manual PN 10023638 for additional war ranty information For a copy of the complete warranty or for information on submitting a warranty claim write to MSA Customer Service Dep...

Отзывы: