13.5 Batteries
WARNING!
Replace the alkaline batteries following the use of the SCBA were the low battery alarm
became active.
Changing of alkaline batteries must be performed in a non-hazardous environment.
Battery modules must only be removed and installed in a non-hazardous environment.
Use only approved alkaline batteries in the alkaline battery module.
Use of other alkaline batteries, or a combination of batteries from different manufacturers, will
affect the performance of the unit and void the Intrinsic Safety Approval.
Failure to follow this warning could result in serious injury or death.
WARNING!
DO NOT dispose of the batteries in fire. They may explode. Follow national regulations for proper
disposal of batteries.
Misuse can result in serious injury or death.
WARNING!
Use only approved alkaline batteries in the alkaline battery module. Use of other batteries, or a
combination of batteries from different manufacturers, will affect the performance of unit and void
the Intrinsic Safety Approval.
CAUTION!
Do not use force to remove or replace the battery pack, otherwise the power module could get
damaged.
With the exception of Energizer EN93, the temperature class for the following list of batteries is
T4. The temperature class for Energizer EN93 batteries is T3C
NOTE:
The temperature class is T4 when the above alkaline cells are installed within the alkaline
battery pack, except the temperature class is T3C when the Energizer EN93 alkaline cells are
installed within the alkaline battery pack.
Battery status can be checked while the SCBA is still in the jump seat, the battery pack
can also be replaced without taking the SCBA out of the jumpseat.
• Duracell Procell PC1400
• Duracell MN1400
• Duracell Quantum LR14
• Panasonic Evolta C-LR14
• Panasonic Industrial LR14XWA
• Industrial Panasonic Powerline
• Rayovac Ultra Pro LR14
• Rayovac LR14
• Rayovac Fusion
• Energizer EN93
• Energizer E93