50
After Use
GB
G1 Integrated SCBA System
NOTE:
Be sure to replace the cylinder with a fully charged one. Complete Inspection, Cleaning
and Disinfecting Procedures outlined in this manual. Ensure that the complete SCBA is clean and
dry. Ensure that full face mask head harness straps and harness adjustment straps are fully
extended. Place the complete SCBA in the storage case or suitable storage location so that it can
be easily reached for emergency use. (See storage instructions.) In situations where users share
the SCBA, the LGDV must be cleaned and disinfected using a disinfectant (see chapter 13.4) to
prevent cross contamination between users.
10.2 Removing the Full Face Mask
(10) Slip the left arm out of the shoulder strap first, then
remove the harness.
(1) Loosen the head harness by pulling the buckles forward using
your fingers.
(2) Grip the chin straps and pull the head harness forward over the
head.
(3) Grip the front of the mask (as shown) and pull the mask away
and down from the user.