8
Specifications
Sensor
Type
Electrochemical
Standard
Range
Optional
Max Range
Zero
Drift
Repeatability
Linearity
Resolution
Response
Time
(1)
Accuracy
Sensor
Life
(2)
5100-03-IT O
2
5-25% Vol
0-25% Vol
+/- 0.1%
+/- 0.2%
+/- 0.2%
+/- 0.1%
<10 sec.
+/- 0.2%
2 years
5100-04-IT CO
0-500 PPM
1200 PPM
+/- 1 PPM
+/- 1 PPM
+/- 1 PPM
0.5 PPM
<35 sec.
+/- 1 PPM
2 years
5100-05-IT H
2
S
(4)
0-100 PPM
100 PPM
+/- 0.5 PPM +/- 1 PPM
+/- 1 PPM
0.1 PPM
<44 sec.
+/- 3 PPM
(5)
2 years
5100-06-IT Cl
2
0-10.0 PPM
10.0 PPM
+/- 0.5 PPM +/- 0.5 PPM
+/- 0.5 PPM 0.1 PPM
<60 sec.
+/- 0.5 PPM
2 years
5100-08-IT ClO
2
0-3.0 PPM
3.0 PPM
+/- 0.5 PPM +/- 0.5 PPM
+/- 0.5 PPM 0.1 PPM
<60 sec.
+/- 0.5 PPM
2 years
5100-10-IT SO
2
0-100 PPM
100 PPM
+/- 0.5 PPM +/- 1 PPM
+/- 1 PPM
0.5 PPM
<20 sec.
+/- 0.5 PPM
2 years
5100-12-IT NO
2
0-20 PPM
20.0 PPM
+/- 0.5 PPM +/- 0.5 PPM
+/- 0.5 PPM 0.2 PPM
<35 sec.
+/- 0.5 PPM
2 years
5100-25-IT NH
3
(3)
0-100 PPM
100 PPM
+/- 1.0 PPM +/- 1.0 PPM
+/- 1.0 PPM +/- 1 PPM
<30 sec.
+/- 1 PPM
1 year
(6)
5100-26-IT HF
(3)
0-10 PPM
10 PPM
--
--
--
0.5 PPM
<30 sec.
+/- 1 PPM
1 year
(6)
5100-88-IT CO
2
(7)
0-5000 PPM 5000 PPM
+/- 1.0 PPM +/- 1.0 PPM
+/- 1.0 PPM +/- 1 PPM
<20 sec.
+/- 2%
2 years
1. Response time to 90% full signal value for applied concentration
2. Sensor life typical for use at standard temperature and pressure with occasional exposure to gas of interest
3. Diffusion via membrane. Requires electrolyte
4. Max range, zero drift, linearity, resolution, and sensor life, have not been verified by FM Approvals
5. Or +/- 10% of reading, whichever is greater
6. Electrolyte recharge only
7. Infrared
Output
Display
Fixed and Scrolling LED
Relays Option
5 Amp, High Alarm, Low Alarm, .25 Amp Trouble all SPDT
Analog Output
Analog 4-20 mA (Trouble 1.5mA, Calibration 2.5mA)
Loop Resistance 800 ohm
Signal Output
Sentry digital bus
Analog 4-20 mA
* 3-wire Non-Isolated
* 4-wire Isolated
Serial RS-485 Modbus RTU
HART
40
SMC 5100-XX-IT Toxic Gas Detector Module
8 Specifications
US
Содержание 5100-03-IT
Страница 5: ...15 5100 88 IT Dimensions 67 SMC 5100 XX IT Toxic Gas Detector Module 5 US...
Страница 20: ...mA Circuit Types 20 SMC 5100 XX IT Toxic Gas Detector Module 4 Installation US...
Страница 21: ...4 20 mA Circuit Type Connections for 5100 XX IT SMC 5100 XX IT Toxic Gas Detector Module 21 US 4 Installation...
Страница 50: ...12 Modbus Memory Map 50 SMC 5100 XX IT Toxic Gas Detector Module 12 Modbus Memory Map US...
Страница 51: ...13 HART SMC 5100 XX IT Toxic Gas Detector Module 51 US 13 HART...
Страница 52: ...52 SMC 5100 XX IT Toxic Gas Detector Module 13 HART US...
Страница 67: ...15 5100 88 IT Dimensions SMC 5100 XX IT Toxic Gas Detector Module 67 US 15 5100 88 IT Dimensions...
Страница 68: ......