MrHeater MHVFDF20BFT Скачать руководство пользователя страница 7

7

Installation Instructions and Owner’s Manual

Universal Unvented Room Heater

(2) Screws

(2) Screws

Figure 6

Attaching Mounting Bracket to Wall

Use holes on each end of mounting bracket to attach 
bracket to wall. These holes are 16 inches apart. Attach 
mounting bracket to wall in one of two following ways.

1.  Attach to wall studs

2.  Attach to wall anchor

Attaching to Wall Stud:

This way is the best providing the strongest mounting in 
wood frame houses. 

Attaching to Wall Anchor: 

This way allows you to attach mounting bracket to hollow 
walls (wall areas between studs) or to solid walls (concrete 
or masonry).
Decide which way best suits your needs. Either method will 
provide a secure hold for the mounting bracket.

1.  Tape mounting bracket to wall where heater will 

be located. Make sure mounting bracket is level. 
For wall stud mounting locate one end of the 
mounting bracket over a wall stud.

WARNING:

 Maintain minimum clearances shown in 

figure 7. If you can, provide greater clearances from the 

floor and joining wall. 

2.  Mark screw locations on wall (see figure 7).
3.  Remove tape and mount bracket from wall.

A

djoining W

all

18” Min.

See clearance 
specs on Pg 3

16” (Lg)
12-9/64” (Sm)

Mark mounting hole locations 
and drill holes where indicated. 
Allow for minimum clearances

Figure 7

Attaching to Wall Stud:

For attaching mounting bracket to wall studs

1. 

Drill holes at marked locations using 9/64” drill bit.

2. 

Place mounting bracket onto wall. Line up holes on 
each end of bracket with hole drilled in wall.

3.  Insert mounting screws through bracket and into 

wall studs.

4.  Tighten screws until mounting bracket is firmly 

fastened to wall studs.

Attaching to Wall using Anchor:

For attaching mounting bracket to hollow walls (wall areas 
between studs) or solid walls (concrete or masonry)

Note: Wall anchors, mounting screws, and spacer 
are in hardware package. The hardware package is 
provided with heater. 

1.  Drill holes at marked locations using 5/16” drill bit. 

For solid walls (concrete or masonry), drill at least 

1” deep.

2.  Fold wall anchor as shown in figure 8.

3.  Insert wall anchor (wings 

first) into hole. Tap anchor 
flush to wall.

4.  For thin walls (1/2” or less) 

insert red key into wall 
anchor. 

5.  Place mounting bracket onto wall. Line up holes 

on each end of bracket with wall anchors.

6.  Insert mounting screws through bracket and into 

wall anchors.

7.  Tighten screws until mounting bracket is firmly 

fastened to wall.

Placing Heater on Mounting Bracket

1. Locate two horizontal slots on back pane of heater 

(see figure 9).

2. 

Place heater onto mounting bracket. Slide horizontal 

slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Mounting Bracket 
mounted to wall

Figure 9

Installing Bottom Mounting Screws

1. Locate two bottom mounting holes. These holes are 

near bottom on back panel of heater (see figure 10).

Screw  
hole

Screw  
hole

Figure 10

 

2. 

Mark screws locations on wall.

3. 

Remove heater from mounting bracket.

Figure 8.

Содержание MHVFDF20BFT

Страница 1: ...our gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen...

Страница 2: ...including benzene which is known to the state of California to cause cancer and cause birth defects or other reproductive harm for more information go to www P65Warnings ca gov Due to high temperature...

Страница 3: ...ilation page 4 3 Keep all air openings in heater clear free of debris or any blockage This will ensure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight unti...

Страница 4: ...1 000 Btu per hour 4 8 m3 per kW of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openi...

Страница 5: ...g room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between the rooms See Ventilation From Inside Building Fig 2 B Vent room directly to the...

Страница 6: ...l by using the floor mounting stands included with the heater If installed on combustible flooring such as carpeting tile or other combustible material other than wood flooring the heater must be plac...

Страница 7: ...s at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws through bracket and into wall stud...

Страница 8: ...line Gas line pressure must be no greater than 10 5 inches of water If gas line pressure is higher heater regulator damage could occur PROPANE LP CAUTION Never connect heater directly to the Propane s...

Страница 9: ...equal to or less than psi 3 5 kPa 2 Cap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening main gas valve...

Страница 10: ...seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This will allow air to bleed from the gas system 6 Wi...

Страница 11: ...ease follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assembly In addition the directions below should also be followed 1 Shut off the un...

Страница 12: ...allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following a Low gas Pressure b Dirty or Partially clogged ODS pilot a Contact local gas co...

Страница 13: ...or replace burner orifice White powder residue forming within burner box or on adjacent walls or furniture When heated vapors from furniture polish wax carpet cleaners etc turn into white powder resid...

Страница 14: ...ssories may be purchased at any Mr Heater Products local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 WWW HEATSTARBYENERCO COM Our office hour...