MrHeater MHVFDF20BFT Скачать руководство пользователя страница 14

20

Installation Instructions and Owner’s Manual

Universal Unvented Room Heater

Mr. Heater, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194

Mr. Heater is a registered trademarks of Mr. Heater Products, Inc.

© 2020, Mr. Heater Products. All rights reserved

PRODUCT REGISTRATION:  Thank you for your purchase.  

Please log in to http://www.egiregistration.com to register your product.

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

Model #

MHVFDF20RTT

MHVFDF30RTT

MHVFDF20BFT

MHVFDF30BFT

READ INSTRUCTIONS CAREFULLY:

 

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS Read and 

follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has 
not read these instructions to assemble, light, adjust or operate the heater.

WARNING:

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS 
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE DIRECT 
FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE AGENCY.

REPLACEMENT PARTS ORDERING INFORMATION:

PURCHASING: 

Accessories may be purchased a

t any Mr. Heater Products local dealer 

or direct from the factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 866-447-2194

WWW.HEATSTARBYENERCO.COM

Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.

Please include the model number, date of purchase, serial number and description of 
problem in all communication.

LIMITED WARRANTY

Enerco Group, Inc. (EGI) w

arrants Mr. Heater Vent free heaters to be free from defects 

in material and workmanship for a period of five years from the date o

f manufacture.  

• During the first two years, EGI will repair or replace this product if it is proven to be 

defective within the first two years and it is returned at customer expense with proof of 

purchase to the location of EGI’s choice.  EGI will be the sole judge of what is determined 

to be a defect.  

• In year’s three to five, EGI will provide replacements for defective parts to the customer 

free of charge. 

This warranty gives you specific legal rights, and you may also have other rights which 
vary from state to state.

Mr. Heater Products, Inc. r

eserves the right to make changes at any time, without notice 

or obligation, in colors, specifications, accessories, materials and models.

Содержание MHVFDF20BFT

Страница 1: ...our gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen...

Страница 2: ...including benzene which is known to the state of California to cause cancer and cause birth defects or other reproductive harm for more information go to www P65Warnings ca gov Due to high temperature...

Страница 3: ...ilation page 4 3 Keep all air openings in heater clear free of debris or any blockage This will ensure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight unti...

Страница 4: ...1 000 Btu per hour 4 8 m3 per kW of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openi...

Страница 5: ...g room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between the rooms See Ventilation From Inside Building Fig 2 B Vent room directly to the...

Страница 6: ...l by using the floor mounting stands included with the heater If installed on combustible flooring such as carpeting tile or other combustible material other than wood flooring the heater must be plac...

Страница 7: ...s at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws through bracket and into wall stud...

Страница 8: ...line Gas line pressure must be no greater than 10 5 inches of water If gas line pressure is higher heater regulator damage could occur PROPANE LP CAUTION Never connect heater directly to the Propane s...

Страница 9: ...equal to or less than psi 3 5 kPa 2 Cap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening main gas valve...

Страница 10: ...seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This will allow air to bleed from the gas system 6 Wi...

Страница 11: ...ease follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assembly In addition the directions below should also be followed 1 Shut off the un...

Страница 12: ...allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following a Low gas Pressure b Dirty or Partially clogged ODS pilot a Contact local gas co...

Страница 13: ...or replace burner orifice White powder residue forming within burner box or on adjacent walls or furniture When heated vapors from furniture polish wax carpet cleaners etc turn into white powder resid...

Страница 14: ...ssories may be purchased at any Mr Heater Products local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 WWW HEATSTARBYENERCO COM Our office hour...