MrHeater MHVFDF20BFT Скачать руководство пользователя страница 3

3

Installation Instructions and Owner’s Manual

Universal Unvented Room Heater

7.   Before using furniture polish, wax, carpet cleaner or 

similar products, turn heater off. If heated the vapors 
from these products may create a white powder residue 
within burner box or on adjacent walls or furniture.

8. 

 Do not use heater if any part has been under water. 

Immediately call a qualified service technician to inspect 
the room heater and to replace any part of the control 
system and any gas control which has been under water.

9. 

Operating heater above elevations of 4,500 feet 

could cause pilot/ODS to shutdown heater.

10.  Always run heater with control knob in a locked 

position. Never set control knob between locked 
positions. Poor combustion and higher levels of carbon 
monoxide may result if control knob is left between 
locked positions.

DANGER:

 Carbon monoxide poisoning may lead to death. 

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning resemble the 
flu, with headaches, dizziness, or nausea. If you have these 
signs, the heater may not be working properly. Get fresh 
air at once! Have heater serviced. Some people are more 
affected by carbon monoxide than others. These include 
pregnant women, persons with heart or lung disease or 
anemia, those under the influence of alcohol, and those at 
high altitudes.

Natural and Propane/LP Gas:

Natural and Propane/LP gases are odorless. An odor making 
agent is added to these gasses. The odor helps you detect 
a gas leak. Gas may be present even though no odor exists. 
Make certain you read and understand all warnings. Keep 
this manual for reference. It is your guide to safe and proper 
operation of this heater.

PRECAUTIONS:

1.  This heater may not be installed in a bedroom, 

bathroom, or any place where a strong wind would shut 
down the appliance.

2. 

This heater needs outside ventilation air to run properly. 

The Oxygen Depletion Sensor (ODS) safety shutoff 
system shuts down the heater if not enough fresh 
air is available. See 

Fresh Air for Combustion and 

Ventilation

, page 4.

3.  Keep all air openings in heater clear, free of debris 

or any blockage. This will ensure that enough air for 
proper combustion enters the heater.

4.  If heater shuts off, do not relight until you provide fresh, 

outside air. If heater keeps shutting off, it requires 
servicing.

5.  Turn off and let cool before servicing. Only a qualified 

service person should service and repair heater.

6.  Do not run heater:

• 

Where flammable liquids or vapors are used or stored

• 

During dusty conditions.

**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**

MODEL

MHVFDF20RTT

MHVFDF30RTT

MHVFDF20BFT

MHVFDF30BFT

Rate (Available) 

20,000 BTU/h (NG)

30,000   BTU/h

20,000 BTU/h

30,000   BTU/h

18,000 BTU/h (Propane/LP)

Type of Gas 

Propane/LP or NG  Only Propane/LP or NG  Only Propane/LP or NG  Only Propane/LP or NG  Only

Ignition 

Battery igniter (1-AA)  Battery igniter (1-AA)  Battery igniter (1-AA)  Battery igniter (1-AA) 

Propane

Manifold Pressure 

10 Inches of Water 

10 Inches of Water 

10 Inches of Water 

10 Inches of Water 

Inlet Gas Pressure (Min) 

11 Inches of Water 

11 Inches of Water 

11 Inches of Water 

11 Inches of Water 

Inlet Gas Pressure (Max)  14 Inches of Water 

14 Inches of Water 

14 Inches of Water 

14 Inches of Water 

Natural 

Gas

Manifold Pressure 

4.5 Inches of Water

4.5 Inches of Water

4.5 Inches of Water

4.5 Inches of Water

Inlet Gas Pressure (Min) 

7 Inches of Water 

7 Inches of Water 

7 Inches of Water 

7 Inches of Water 

Inlet Gas Pressure (Max)  14 Inches of Water 

14 Inches of Water 

14 Inches of Water 

14 Inches of Water 

Electrical  Rating /Blower

120V, 60Hz , 1Ø

120V, 60Hz , 1Ø

120V, 60Hz , 1Ø

120V, 60Hz , 1Ø

Thermostatic Control 

Yes

Yes

Yes

Yes

Clearances

Top

36” (91.4 cm) 

36” (91.4 cm) 

36” (91.4 cm) 

36” (91.4 cm) 

Sides

10” (25.4 cm) 

10” (25.4 cm) 

10” (25.4 cm) 

10” (25.4 cm) 

Floor (min to top of carpet)

3” (7.6 cm) 

3” (7.6 cm) 

3” (7.6 cm) 

3” (7.6 cm) 

Fabric / flammable objects

36” (91.4 cm) 

36” (91.4 cm) 

36” (91.4 cm) 

36” (91.4 cm) 

CONTENTS

WARNINGS

 ...............................................

2

SPECIFICATIONS ........................................3

PRECAUTIONS

 ...........................................3

DETERMINING THE TYPE 

OF HEATER LOCATION SPACE

 ................4

INSTALLATION ..........................................6

FASTENING HEATER TO WALL

 ...................6

FLOOR MOUNTING AWAY FROM WALL

 ....

8

CONNECTING TO GAS SUPPLY ..................

8

OPERATING YOUR HEATER

 ...................... 10

CLEANING AND MAINTENANCE ............. 11

TROUBLESHOOTING

 ...............................

12

PARTS LIST AND DIAGRAM

 .................

14-15

WARRANTY 

 ...........................................

18

Содержание MHVFDF20BFT

Страница 1: ...our gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen...

Страница 2: ...including benzene which is known to the state of California to cause cancer and cause birth defects or other reproductive harm for more information go to www P65Warnings ca gov Due to high temperature...

Страница 3: ...ilation page 4 3 Keep all air openings in heater clear free of debris or any blockage This will ensure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight unti...

Страница 4: ...1 000 Btu per hour 4 8 m3 per kW of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openi...

Страница 5: ...g room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between the rooms See Ventilation From Inside Building Fig 2 B Vent room directly to the...

Страница 6: ...l by using the floor mounting stands included with the heater If installed on combustible flooring such as carpeting tile or other combustible material other than wood flooring the heater must be plac...

Страница 7: ...s at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws through bracket and into wall stud...

Страница 8: ...line Gas line pressure must be no greater than 10 5 inches of water If gas line pressure is higher heater regulator damage could occur PROPANE LP CAUTION Never connect heater directly to the Propane s...

Страница 9: ...equal to or less than psi 3 5 kPa 2 Cap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening main gas valve...

Страница 10: ...seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This will allow air to bleed from the gas system 6 Wi...

Страница 11: ...ease follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assembly In addition the directions below should also be followed 1 Shut off the un...

Страница 12: ...allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following a Low gas Pressure b Dirty or Partially clogged ODS pilot a Contact local gas co...

Страница 13: ...or replace burner orifice White powder residue forming within burner box or on adjacent walls or furniture When heated vapors from furniture polish wax carpet cleaners etc turn into white powder resid...

Страница 14: ...ssories may be purchased at any Mr Heater Products local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 WWW HEATSTARBYENERCO COM Our office hour...