![MrHeater MHVFDF20BFT Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/mrheater/mhvfdf20bft/mhvfdf20bft_operating-instructions-and-owners-manual_1845896003.webp)
3
Installation Instructions and Owner’s Manual
Universal Unvented Room Heater
7. Before using furniture polish, wax, carpet cleaner or
similar products, turn heater off. If heated the vapors
from these products may create a white powder residue
within burner box or on adjacent walls or furniture.
8.
Do not use heater if any part has been under water.
Immediately call a qualified service technician to inspect
the room heater and to replace any part of the control
system and any gas control which has been under water.
9.
Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10. Always run heater with control knob in a locked
position. Never set control knob between locked
positions. Poor combustion and higher levels of carbon
monoxide may result if control knob is left between
locked positions.
DANGER:
Carbon monoxide poisoning may lead to death.
Carbon Monoxide Poisoning:
Early signs of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If you have these
signs, the heater may not be working properly. Get fresh
air at once! Have heater serviced. Some people are more
affected by carbon monoxide than others. These include
pregnant women, persons with heart or lung disease or
anemia, those under the influence of alcohol, and those at
high altitudes.
Natural and Propane/LP Gas:
Natural and Propane/LP gases are odorless. An odor making
agent is added to these gasses. The odor helps you detect
a gas leak. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep
this manual for reference. It is your guide to safe and proper
operation of this heater.
PRECAUTIONS:
1. This heater may not be installed in a bedroom,
bathroom, or any place where a strong wind would shut
down the appliance.
2.
This heater needs outside ventilation air to run properly.
The Oxygen Depletion Sensor (ODS) safety shutoff
system shuts down the heater if not enough fresh
air is available. See
Fresh Air for Combustion and
Ventilation
, page 4.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will ensure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide fresh,
outside air. If heater keeps shutting off, it requires
servicing.
5. Turn off and let cool before servicing. Only a qualified
service person should service and repair heater.
6. Do not run heater:
•
Where flammable liquids or vapors are used or stored
•
During dusty conditions.
**Operating heater above elevations of 4,500 feet could cause pilot/ODS to shutdown heater.**
MODEL
MHVFDF20RTT
MHVFDF30RTT
MHVFDF20BFT
MHVFDF30BFT
Rate (Available)
20,000 BTU/h (NG)
30,000 BTU/h
20,000 BTU/h
30,000 BTU/h
18,000 BTU/h (Propane/LP)
Type of Gas
Propane/LP or NG Only Propane/LP or NG Only Propane/LP or NG Only Propane/LP or NG Only
Ignition
Battery igniter (1-AA) Battery igniter (1-AA) Battery igniter (1-AA) Battery igniter (1-AA)
Propane
Manifold Pressure
10 Inches of Water
10 Inches of Water
10 Inches of Water
10 Inches of Water
Inlet Gas Pressure (Min)
11 Inches of Water
11 Inches of Water
11 Inches of Water
11 Inches of Water
Inlet Gas Pressure (Max) 14 Inches of Water
14 Inches of Water
14 Inches of Water
14 Inches of Water
Natural
Gas
Manifold Pressure
4.5 Inches of Water
4.5 Inches of Water
4.5 Inches of Water
4.5 Inches of Water
Inlet Gas Pressure (Min)
7 Inches of Water
7 Inches of Water
7 Inches of Water
7 Inches of Water
Inlet Gas Pressure (Max) 14 Inches of Water
14 Inches of Water
14 Inches of Water
14 Inches of Water
Electrical Rating /Blower
120V, 60Hz , 1Ø
120V, 60Hz , 1Ø
120V, 60Hz , 1Ø
120V, 60Hz , 1Ø
Thermostatic Control
Yes
Yes
Yes
Yes
Clearances
Top
36” (91.4 cm)
36” (91.4 cm)
36” (91.4 cm)
36” (91.4 cm)
Sides
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
10” (25.4 cm)
Floor (min to top of carpet)
3” (7.6 cm)
3” (7.6 cm)
3” (7.6 cm)
3” (7.6 cm)
Fabric / flammable objects
36” (91.4 cm)
36” (91.4 cm)
36” (91.4 cm)
36” (91.4 cm)
CONTENTS
WARNINGS
...............................................
2
SPECIFICATIONS ........................................3
PRECAUTIONS
...........................................3
DETERMINING THE TYPE
OF HEATER LOCATION SPACE
................4
INSTALLATION ..........................................6
FASTENING HEATER TO WALL
...................6
FLOOR MOUNTING AWAY FROM WALL
....
8
CONNECTING TO GAS SUPPLY ..................
8
OPERATING YOUR HEATER
...................... 10
CLEANING AND MAINTENANCE ............. 11
TROUBLESHOOTING
...............................
12
PARTS LIST AND DIAGRAM
.................
14-15
WARRANTY
...........................................
18