MrHeater MHVFDF20BFT Скачать руководство пользователя страница 1

1

Installation Instructions and Owner’s Manual

Universal Unvented Room Heater

Mr. Heater Products, Inc., 4560 W. 160

TH

 ST., CLEVELAND, OHIO 44135 · 866-447-2194

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference. 

UNIVERSAL UNVENTED ROOM HEATER

OPERATING INSTRUCTIONS 

AND OWNER’S MANUAL

Model #

MHVFDF20RTT

MHVFDF30RTT

MHVFDF20BFT

MHVFDF30BFT

READ INSTRUCTIONS CAREFULLY:

 

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS Read and 

follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has 
not read these instructions to assemble, light, adjust or operate the heater.

 WARNING: If the information in this manual is not followed exactly, a fire or explosion 

may result causing  property damage, personal injury, or loss of life. 

 

-

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 
other appliance.

 

-

WHAT TO DO IF YOU SMELL GAS

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• 

If you cannot reach your gas supplier, call the fire department.

 

-

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. 
Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for 
Combustion and Ventilation section on page 4 of this manual. 

This appliance may be installed in an aftermarket permanently manufactured (mobile) home, 
where not prohibited by local codes. 
This appliance is only for use with propane or natural gas.
This appliance is equipped with a simple means to switch between propane and natural gas. 
Field conversion by any other means including the use of a kit is not permitted.

 WARNING: Do not attempt to access 

or change the setting of the fuel selection 
means.
Access to and adjustment of the fuel 
selection means must only be performed by 
a qualified service person when connecting 
this appliance to a specified fuel supply at the 
time of installation.
Change of the selector setting to other 
than the fuel type specified at the time of 
installation could damage this appliance and 
render it inoperable.
The installer shall replace the access cover 
before completing the installation and 
operating this appliance.

Blue Flame Heaters

Plaque Heaters 

MHVFDF20RTT

MHVFDF20BFT

MHVFDF30RTT

MHVFDF30BFT

Содержание MHVFDF20BFT

Страница 1: ...our gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen...

Страница 2: ...including benzene which is known to the state of California to cause cancer and cause birth defects or other reproductive harm for more information go to www P65Warnings ca gov Due to high temperature...

Страница 3: ...ilation page 4 3 Keep all air openings in heater clear free of debris or any blockage This will ensure that enough air for proper combustion enters the heater 4 If heater shuts off do not relight unti...

Страница 4: ...1 000 Btu per hour 4 8 m3 per kW of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openi...

Страница 5: ...g room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between the rooms See Ventilation From Inside Building Fig 2 B Vent room directly to the...

Страница 6: ...l by using the floor mounting stands included with the heater If installed on combustible flooring such as carpeting tile or other combustible material other than wood flooring the heater must be plac...

Страница 7: ...s at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws through bracket and into wall stud...

Страница 8: ...line Gas line pressure must be no greater than 10 5 inches of water If gas line pressure is higher heater regulator damage could occur PROPANE LP CAUTION Never connect heater directly to the Propane s...

Страница 9: ...equal to or less than psi 3 5 kPa 2 Cap off open end of gas pipe where equipment shutoff valve was connected 3 Pressurize supply piping system by either using compressed air or opening main gas valve...

Страница 10: ...seconds Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for about 30 seconds This will allow air to bleed from the gas system 6 Wi...

Страница 11: ...ease follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assembly In addition the directions below should also be followed 1 Shut off the un...

Страница 12: ...allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following a Low gas Pressure b Dirty or Partially clogged ODS pilot a Contact local gas co...

Страница 13: ...or replace burner orifice White powder residue forming within burner box or on adjacent walls or furniture When heated vapors from furniture polish wax carpet cleaners etc turn into white powder resid...

Страница 14: ...ssories may be purchased at any Mr Heater Products local dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 866 447 2194 WWW HEATSTARBYENERCO COM Our office hour...