mrcool.com
Installation Checklist
23
59
1.
Have you maintained the required clearances from building openings and intake
air vents?
2.
Have you minimized the distance between the water heater and the
vent termination?
3.
Have you minimized the distance between the water heater and major fixtures?
4.
Have you maintained the proper service and maintenance clearances?
5.
Is the water heater and vent piping clear of combustible materials, including
clothing, cleaning materials, and rags?
6.
Does the gas supply match what is specified on the water heater rating plate?
7.
Is the gas line at least 1/2 or 3/4 in inner diameter?
8.
Is the gas supply line sufficient in length and diameter to deliver the required BTUs?
9.
Have you measured the pressure of the gas supply line?
10.
Is the gas supply pressure within the recommended ranges specified in this manual?
11.
Is the gas supply line equipped with a manual full port valve?
12.
Have you tested the gas line pressure and all fittings for leaks?
13.
Has the gas company inspected the installation, if required?
14.
Is the water supply pressure sufficient (greater than 40 PSI)?
15.
Have you installed shut off valves on the inlet and outlet to facilitate cleaning of the
inlet water filter?
16.
Have you bled the air out at each fixture?
17.
Have you checked each fixture to ensure hot water is being supplied?
18.
Have you cleaned the inlet water filter?
19.
Have you installed an approved pressure relief valve on the water heater?
20.
Does the rating of the pressure relief valve match or exceed the maximum BTU
rating of the water heater?
21.
Is the pressure relief valve at least 3/4 in. inner diameter?
22.
Have you installed the pressure relief valve on the hot water outlet pipe near the
water heater?
23.
Have you installed a discharge drain tube from the pressure relief valve to within
6-12 in. (150-300 mm) of the floor?
24.
Have you installed a condensate drain line from the water heater to a drain or
laundry tub?
Gas Supply Connection
Condensate Drain Connection
No. Items
Check box
Water Heater Installation
Water Supply Connection
Pressure Relief Valve Connection
Содержание MHWH199NC U Series
Страница 8: ...mrcool com 3 Product Overview Accessories 7 Fig 3 1 1 5 3 6 4 2 7 8 10 9...
Страница 24: ...23 Measuring The Inlet Gas Pressure Fig 9 1 Fig 9 2 Fig 9 4 mrcool com Fig 9 5 Fig 9 3...
Страница 65: ...Electrician and or HVAC Technician License Installation Date Installation location Serial number...