NOTE
NOTE
mrcool.com
Operation
Range of temperature setting
Accuracy
42
•
The temperature setting is from 95 to 140° (35-60°C) when burner is off. When burner is on,
temperature setting is from 95 to 122° (35~50°C) if current set temperature is below 122°F;
• The temperature setting is from 95 to 140° (35-60°C) if current set temperature is above 122°F.
If set temperature is adjusted to a value that is lower than 122°F (50°C), the range becomes
95-122°F (35~50°C).
To reset the default setting temperature, press the
ENTER
button for 3 seconds until the set temperature
on the display flashes while the power is on. Then, press the or keys to reset the default temperature
setting.
To switch from current temperature to the default temperature, press the
ENTER
button while the burner is
on. The buzzer will beep if successful.
If you try to switch the default temperature by pressing ENTER while the burner is on, the system
will not allow this and the buzzer will sound twice.
Set or reset default setting temperature
95°F ~ 140°F
1°F
1°C
35°C ~ 60°C