Troubleshooting guide
The green LED “Standard“ or “StartStop“ does not light up
Check for correct connection and specification of the power adapter.
Ensure that the original power adapter is used.
Specifications: 9 V / DC, 1A
Polarity:
The foot pedal does not work
Check for correct connection of the foot pedal.
Ensure that the foot pedal socket and plug is not twisted or broken.
No Flame
In case of ignition or flame faliure check if the burner head is clogged. Verify the input
pressure of the used gas. Ensure that the correct nozzle is installed in the unit.
Nozzle
N
: natural gas, input pressure: 18-25 mbar
Nozzle
P
: propane / butane gas, input pressure: 47-57 mbar
LED “Burner head HOT / BHC“ flashes / Inspection of the burner head (clogging)
Take care that there are no liquids or other substances at the Bypass (area between the
inner and the outer ring)
Especially remove substances in the
marked areas at the electrodes. If there
are contaminants in this area, the flame
cannot encircle the electrodes correctly.
Clean this areas with a brush. The
burner head can be cleaned with
customary commercial disinfectants,
or it can be sterilized in an autoclave or
washed in a dishwasher.
In operating mode “Button“ or Pedal “StartStop“ flame burns 30 seconds, only
BHC time limit is active, LED “Burner head hot / BHC“ is blinking. The burner head is
clogged and must be cleaned
(see paragraph 3 and 5.1)
.
Flame too small / large / soft
Check the position of the air and gas adjustment.
Check if the correct nozzle is installed.
Nozzle
N
: natural gas, 18-25 mbar
Nozzle
P
: propane / butane gas, 47-57 mbar
Check if the drilling of the active nozzle is blocked. Unscew the active nozzle.
(see paragraph 1)
If the drilling is blocked clean with a brush or compressed air.
No ignition spark / LED “Burner head HOT / BHC“ flashes but the burner head is clean
Check if the ceramic electrodes are in good condition. In some cases the electrodes
may break. To check move the ends of the electrodes. If they are not moving they
should be okay. If they are moving more than 0.5 mm the electrodes are broken. The
electrodes can be dismantled and changed by the user.
(see paragraph 5.1)
+
-