19
(
6
)
“
”Is the UV lamp timing increase button, shut down the fun, turn off the fluorescent lamp
under the display state of the display screen, press the
button, the display screen will display
the timing time of the UV lamp. After each press, the buzzer will ring once, and the set time will
increase one minute.
(
7
)
“
”Is the UV lamp timing decrease button; after each press, the buzzer will ring once, and
the set time will decrease one minute; according to the required length of time to set the time (the
timing time range of UV lamp is 0-90Min, at the time of leaving the factory , it is set to the
maximum, 90Min).
Note: Because the UV lamp will start working after 90S of the setting, the operator will complete
the setting in 90S and leave the operating area quickly.
(
8
)
“
”Is the fan velocity decrease button; when the fan is running, if the number of“
▊
”is
greater than 1, after each press, the velocity will be decreased one gear, and the buzzer will ring
once, this operation can not be stopped until there is only one “
▊
”.
(
9
)
“
”Is the fan velocity increase button; when the fan is running, if the number of“
▊
”is
less than 9, after each press, the velocity will be increased one gear, and the buzzer will ring once,
this operation can not be stopped until there are9 “
▊
”.
(
10
)
Display screen display: When the power is turned on, the display contents from the top to the
bottom are
▊▊▊▊▊▊▊▊▊
FAN, indicating the working velocity of the fan is weak; the
corresponding below displays the velocity in the current state; the right display the time (the
adjustment of the time will be described below); UV display the working time of the UV lamp;
WORK TIME displays the working time of the filter.
(
11
)
Adjustment of the clock: in the standby mode, press the fluorescent lamp button continuously,
after one alarm sound, enters into the clock set state, at this time, the minute bit starts to flash, adjust
the minutebit by pressing the increase, decrease buttons, and then press the fan button, then the hour
bit starts to flash, adjust the hour bit by pressing the increase, decrease buttons, minute and hour bits
should be adjusted to the current time, and then press the fluorescent lamp button again to save the
clock after one alarm sound.
G. Waterproof socket
Waterproof socket is set at the control panel of the operating area to supply power to the equipment
in the operating area. The socket is located on both sides of the control panel (as is shown in Figure
14). When the socket is required to be used, turn on the power of the equipment and press the
display socket button (as is shown in Figure 15), the socket can be powered.
(
1
)
The power of the equipment used on the socket does not exceed 500W;
H. protective tube
The protective tube is located on the upper right side of the rear cabinet of the product, and the
corresponding protective tube socket and the power socket are installed with socket and live line
protective tube respectively, the specification of the protective tube should be consistent with the
label contents pasted right below, and the replacement should be according to the label contents.
Содержание FH-12-DB