MRC AUDIO EQ
Limit
36
The registered records are the next:
-
Sound measurement data, this is the sound levels, with adjustable minimum level to
register and register frequency.
-
The beginning and ending of working sessions. The start and end of a working session
conditions are adjustable.
-
Microphone, level and efficiency alarms.
-
External alarms if these are connected to the corresponding input pin in the auxiliary
AUX connector located at the back of the unit, as described in section 7.10 Preferences
of this manual.
-
The moment of switching off or on of the unit.
-
The moment when a change in configuration is made; it registers the name of the
authorized installer that makes the changes.
-
Master password access is registered, together with the name of the authorized installer
that has used it.
-
The moment when a download of events is made.
-
When is connected to Internet
-
When disconnect from Internet
-
When compare levels in each band to detect any misalignment
Sound Level Measurement Data:
EQ
Limit
has the capacity to measure and register the next sound parameters:
- Instantaneous SPL of microphone 1 (Leq 5 seconds).
- Leq with adjustable integration time, for microphone 1.
- Percentile L90 for microphone 1.
- Percentile L10 for microphone 1.
- Instantaneous SPL of microphone 2 (Leq 5 seconds).
- Leq with adjustable integration time, for microphone 2.
- Percentile L90 for microphone 2.
- Percentile L10 for microphone 2.
- Instantaneous level for Line In (Leq 5 seconds).
- Instantaneous level for Line Out (Leq 5 seconds).
- Leq with adjustable integration time for Line Out.
- Maximum permitted level (limiting level) for that moment.
- Attenuation applied by the limiter in that moment.
The sound level measurements are stored in the non-volatile events memory in a periodic
manner with a frequency configured by the user. The minimum level to register is also
configurable. If the instantaneous level of microphone 1 is less than this minimum, none of the
sound parameters will be stored into the events memory even if the period time has elapsed.
All this stored data can be downloaded directly from the limiter via the USB connection; after
downloading this data is kept in a data base in the PC and can be analysed in off line mode