H O M E O W N E R

S E C T I O N

As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient
installation and operation of this steam bath system. These are types of potential hazards that may occur during installation and operation:

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation, which, if not avoided may result in minor or moderate injury or product damage.

This highlights information that is especially relevant to a problem-free installation.

All information in these instructions is based on the latest product information available at the time of publication. Sussman-Automatic Corporation
reserves the right to make changes at any time without notice. More current instructions may be available at www.mrsteam.com.

IMPORTANT SAFETY INFORMATION

Applies to 1-17

1. Steam rooms contain steam and elevated temperatures.

Please read and observe all warnings in this manual
before using a steam room.

2. Discontinue use of the steam generator and control if the

steam generator or control are damaged or otherwise
not functioning properly. Using damaged equipment may
result in an inoperative or hazardous installation

3. The MAX series of steam generators are for residential

use only. Commercial or other nonresidential applications
void the warranty and may adversely affect product
performance and may represent a safety hazard.

4. Read these instructions before installation, operation or

service.

5. Although the MAX steambath generators have been fully

qualified for shipment by MrSteam, the following must
be reviewed for proper, safe and enjoyable steam
bathing:

- Verify that the model and accessories specifications are

correct for the incoming line voltage.

- Ensure steambath generator has been correctly sized for

the steam room. Pay particular attention to room volume
and construction. If any questions, please refer to
MrSteam sizing and selection guide on page 6 or call
MrSteam.

6. Supervise children at all times.
7. Steam is hot and can cause injury or death if improperly

used.

8. Prolonged use of the steam system can raise excessively

the internal human body temperature and impair the
body’s ability to regulate its internal temperature (hyper-
thermia). Limit your use of steam to 10-15 minutes until
you are certain of your body’s reaction.

9. Excessive temperatures have a high potential for causing

fetal damage during the early months of pregnancy.
Pregnancy or possibly pregnant women should consult a
physician before using a steam bath.

10. Obese persons and persons with a history of heart dis-

ease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before
using a steambath.

11. Persons using medication should consult a physician

before using a steambath since some medication may
induce drowsiness while other medications may affect
heart rate, blood pressure and circulation.

12. Electric shock hazard. MrSteam steam generators are

connected to high voltage and contain live electrical
components. All installation and service to be per-
formed by qualified and licensed electricians and
plumbers only. Installation or service by unqualified
persons or failure to use MrSteam parts may result in
property damage or in a personal injury.

13. If you are pregnant, have a coronary condition, are in

poor health, are being treated for any other medical
condition, or are using medication or drugs, MrSteam
recommends that you obtain the approval of a physi-
cian before use. For information about this product and
safety issues, call 1.800.76.STEAM.

14.

Do not install or use any iSteam

®

, AirTempo

®

, TempoPlus

®

,

iTempo

®

, HomeWizard

®

or iGenie

®

controls without read-

ing and understanding the Control Installation and
Operation Manual. Failure to read and understand these
instructions may result in an inoperative or hazardous
installation.

15. If an iSteam, AirTempo, iTempo or iTempo/Plus control is

installed outside the steam room a Remote Temperature
Probe (PN MSTS) must be installed inside the steam room
per installation instructions supplied with the Remote
Temperature Probe. Failure to use a Remote Temperature
Probe or failure to install according to instructions will
result in an inoperative control and overheating of the
steam room.

16. To prevent slip and fall hazards non-slip strips must be

installed on the steam room floor.

17. Do not alter or modify any MrSteam product. Doing so

may result in an inoperative or hazardous installation and
will void the warranty.

Содержание MX4E

Страница 1: ...m Feel Good Inc ____________________ IMPORTANT Leave this material with the homeowner ____________________ Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models...

Страница 2: ...Wiring Diagrams 14 Connecting Multiple Generators 15 POST INSTALLATION INFORMATION Generator and Start Up Checkout 15 Troubleshooting 16 17 OPTIONS ACCESSORIES Controls 18 AutoFlush 19 20 Condensation...

Страница 3: ...fore using a steam bath Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or product damage This highlights information that is especially relevan...

Страница 4: ...EATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL DRUGS OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS 5 DO NOT CONTACT STEAMHEAD OR STEAM AT THE STEAMHEAD REDUCE THE RISK OF SLIPPING...

Страница 5: ...lity can affect steam generator efficiency and or result in steam generator damage Water contains impurities in solution and suspension These impurities con centrate in the generator The concentration...

Страница 6: ...ration and remain hot after shut down for a period of time Provide appropriate protection including insulating plumbing lines Avoid plumbing runs and steamhead locations that can come in contact with...

Страница 7: ...mensions Wt lbs MX4E 20 84 3 483 678 2 7 251 8 L x 203 4 H x 77 8 D 67 MX5E 24 100 1 679 822 3 2 251 8 L x 203 4 H x 77 8 D 67 MX6E 30 125 2 0 823 964 4 0 251 8 L x 203 4 H x 77 8 D 67 Applies to 1 8...

Страница 8: ...Applies to 1 2 1 Do not install MAX series inside a vanity or other small enclosed spaces Do not install under the steam room bench Installing the MAX steam generator in a small enclosed space may res...

Страница 9: ...TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS Connecting power directly to the elements will result in a dry fire and result in elevated tempera tures and a fire hazard MX...

Страница 10: ...nerators 12 ft All Models 103917 Tandem Cable for up to 5 generators 30 ft All Models 103990 60 Cable for iTempo AirTempo Control 60 ft All Models 104117 30 Cable for iSteam AirTempo iTempo 30 ft All...

Страница 11: ...t a designated location on the steam piping See the MrSteam AromaSteam Operation and Instruction Manual PN 100402 for installation information before the steam piping is installed at the technical dow...

Страница 12: ...g with fiberglass pipe insulation or similar insulation rated 212 F or higher 8 Pitch steam piping 1 4 per foot towards steamhead or steam generator to avoid valleys and trapping of conden sate Runnin...

Страница 13: ...any material product or surface from deteriorating do not locate the steamheads where direct steam emission would come in direct contact with non heat or moisture resisitant products or materials 4 To...

Страница 14: ...or illustrative purposes only ELECTRICAL Applies to 1 9 1 Never use damaged equipment doing so may result in an inoperative or hazardous installation 2 All electrical wiring installation to be perform...

Страница 15: ...E 208 240 VOLT WIRING DIAGRAM MODELS MX4E MX5E MX6E mr steam Installation Operation Maintenance Manual __________________________________________________________________________ CONTACTOR EXPRESS STEA...

Страница 16: ...N Secondary Unit Primary Unit Connector wires will be reverse color on secondary generator Power Supply Water Feed Line Applies to 1 2 1 Install each unit as in a single installation Install the gener...

Страница 17: ...erify that the green light on the Circuit Board is ON Step 5 Push the white Force On test button on the circuit board see page 17 to run the generator for a 10 minute test cycle Make sure the steam ro...

Страница 18: ...e to be performed by qualified and licensed electricians and plumbers only Installation or service by unqualified persons or failure to use MrSteam parts may result in property damage or in a personal...

Страница 19: ...id unintentional steambath operation do not locate the control where other controls accessories shower heads valves body sprays or similar within the shower could cause confusion or interfere with the...

Страница 20: ...y location where accidental contact with drain water may occur In the event of a power failure the AutoFlush valve will open and may discharge boiling water causing a scalding hazard 4 Do not connect...

Страница 21: ...to condensation pan and cause a leak and property damage 7 See pages 10 11 for complete drain line and plumbing instructions 10 The steam generator drains by gravity Plumb all drain lines accordingly...

Страница 22: ...t cable length iSteam3 Control iSteam3 BK Limited by 30 ft or 60 ft cable iSteam3 WH AirTempo Control AIRTBK Designer Code Consider wireless range maximum range is 60 ft AIRTWH Designer Code iTempo Co...

Страница 23: ...injury or death if improperly used 8 Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyp...

Страница 24: ...ng a suitable and safe steam room 17 MrSteam steam generators are intended to be operated with MrSteam controls and accessories only and are to be installed strictly in accordance with the specific in...

Страница 25: ...n before using aromatherapy Applies to 1 6 1 Use essential oils with caution Essential oils are for external use only Keep out of reach of children Essential oils are highly concentrated and are poten...

Страница 26: ...410 S La Cienega Blvd Inglewood CA 90301 TEL 1 800 72 STEAM 2020 Sussman Automatic Corporation I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package...