12

mr.steam

®

Installation, Operation & Maintenance Manual

___________________________________________________________________________

Applies to 1-2

1. MAX Steam Generators must be installed with two or more

steamheads. Using less than two steamheads will result in too
much steam coming out of one steamhead and may result in
scalding and personal injury.

2. Because the steamhead and direct steam emissions are very hot, locate

the steamheads where incidental contact by bather with the steamheads
or direct steam emission cannot occur.

Applies to 3-4

3. Do not disassemble steamheads. The steamheads are shipped fully

assembled and requires no additional assembly. Disassembly of the
steamheads may result in a burn hazard.

4. Seal the gap between the wall and the steam supply pipe with silicone

(or other 212˚F heat resistant sealant) as required to create a moisture
seal. Failure to create a moisture seal may allow moisture to enter the
wall cavity and cause property damage.

Applies to 5-6

5. To preserve the steamhead finish, do not use wrench or other tools to tighten. Do

not use abrasive cleansers or chemicals. Use only water with mild soap and a non-
abrasive sponge.

6. Contact the supplier of acrylic, fiberglass and other non-heat resistant enclosures

for recommended steamhead location. Use Acrylic Shield PN 103938RD (round)
or PN 103938SQ (square). See instructions provided with steam shield.

STEP 1

1. Locate the steamheads 6-12 inches above floor.

2. For tub/shower enclosures, install the steamheads 6 inches above tub top edge.

3. To prevent door seals or any material, product or surface from deteriorating,

do not locate the steamheads where direct steam emission would come in
direct contact with non-heat or moisture-resisitant products or materials.

4. To reduce noise, do not locate steamhead within 12" from a wall.

STEP 2

Provide 1

1

2

" clearance holes around the steam pipes.

STEP 3

Secure a bronze drop ear fittings to a header and run a 3/4" copper steam piping

from the steam generator to tee fitting and 1/2" steam piping after tee fitting to the
drop ear fittings. Install a temporary nipples (6" or longer) in the drop ear fittings to
locate the steamheads after the wall is finished.

STEP 4

After the wall has been finished, mark the surface of the wall for both nipples.
Remove the nipples and measure the portion that was in the wall (the end to your
mark). Subtract 1⁄4" from that dimension and select a brass nipples of that length to
finish the installation.

STEP 5

Wrap teflon tape around the threads of the new nipples and screw the nipples into the
steamheads. Wrap teflon tape around the threads of the nipples and screw the nipples
and steamhead assemblies into the drop ear fittings in the wall. Hand tightening is
sufficient when teflon or equal pipe thread sealing compound is used. The steamheads
should be flush with the oil well facing up.

STEAMHEAD INSTALLATION

steamhead

Locating Nipple

All

 

drawings

 

are

 

for

 

illustrative

 

purposes

 

only

Steam
Supply Pipe

End of pipe to be recessed
1/4" (

without Acrylic Shield

)

1/8" (

with Acrylic Shield)

1/8" minimum clearance
required when Acrylic Shield
is used. See installation
instructions provided with the
Acrylic Shield.

Apply with silicone or equal

sealant as required for

moisture seal.

Use Teflon

®

or

equal sealant on

pipe threads

Oil Well

STEP 3

STEP 4

STEP 5

Drop Ear
Fitting

Содержание MX4E

Страница 1: ...m Feel Good Inc ____________________ IMPORTANT Leave this material with the homeowner ____________________ Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models...

Страница 2: ...Wiring Diagrams 14 Connecting Multiple Generators 15 POST INSTALLATION INFORMATION Generator and Start Up Checkout 15 Troubleshooting 16 17 OPTIONS ACCESSORIES Controls 18 AutoFlush 19 20 Condensation...

Страница 3: ...fore using a steam bath Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or product damage This highlights information that is especially relevan...

Страница 4: ...EATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL DRUGS OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS 5 DO NOT CONTACT STEAMHEAD OR STEAM AT THE STEAMHEAD REDUCE THE RISK OF SLIPPING...

Страница 5: ...lity can affect steam generator efficiency and or result in steam generator damage Water contains impurities in solution and suspension These impurities con centrate in the generator The concentration...

Страница 6: ...ration and remain hot after shut down for a period of time Provide appropriate protection including insulating plumbing lines Avoid plumbing runs and steamhead locations that can come in contact with...

Страница 7: ...mensions Wt lbs MX4E 20 84 3 483 678 2 7 251 8 L x 203 4 H x 77 8 D 67 MX5E 24 100 1 679 822 3 2 251 8 L x 203 4 H x 77 8 D 67 MX6E 30 125 2 0 823 964 4 0 251 8 L x 203 4 H x 77 8 D 67 Applies to 1 8...

Страница 8: ...Applies to 1 2 1 Do not install MAX series inside a vanity or other small enclosed spaces Do not install under the steam room bench Installing the MAX steam generator in a small enclosed space may res...

Страница 9: ...TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS Connecting power directly to the elements will result in a dry fire and result in elevated tempera tures and a fire hazard MX...

Страница 10: ...nerators 12 ft All Models 103917 Tandem Cable for up to 5 generators 30 ft All Models 103990 60 Cable for iTempo AirTempo Control 60 ft All Models 104117 30 Cable for iSteam AirTempo iTempo 30 ft All...

Страница 11: ...t a designated location on the steam piping See the MrSteam AromaSteam Operation and Instruction Manual PN 100402 for installation information before the steam piping is installed at the technical dow...

Страница 12: ...g with fiberglass pipe insulation or similar insulation rated 212 F or higher 8 Pitch steam piping 1 4 per foot towards steamhead or steam generator to avoid valleys and trapping of conden sate Runnin...

Страница 13: ...any material product or surface from deteriorating do not locate the steamheads where direct steam emission would come in direct contact with non heat or moisture resisitant products or materials 4 To...

Страница 14: ...or illustrative purposes only ELECTRICAL Applies to 1 9 1 Never use damaged equipment doing so may result in an inoperative or hazardous installation 2 All electrical wiring installation to be perform...

Страница 15: ...E 208 240 VOLT WIRING DIAGRAM MODELS MX4E MX5E MX6E mr steam Installation Operation Maintenance Manual __________________________________________________________________________ CONTACTOR EXPRESS STEA...

Страница 16: ...N Secondary Unit Primary Unit Connector wires will be reverse color on secondary generator Power Supply Water Feed Line Applies to 1 2 1 Install each unit as in a single installation Install the gener...

Страница 17: ...erify that the green light on the Circuit Board is ON Step 5 Push the white Force On test button on the circuit board see page 17 to run the generator for a 10 minute test cycle Make sure the steam ro...

Страница 18: ...e to be performed by qualified and licensed electricians and plumbers only Installation or service by unqualified persons or failure to use MrSteam parts may result in property damage or in a personal...

Страница 19: ...id unintentional steambath operation do not locate the control where other controls accessories shower heads valves body sprays or similar within the shower could cause confusion or interfere with the...

Страница 20: ...y location where accidental contact with drain water may occur In the event of a power failure the AutoFlush valve will open and may discharge boiling water causing a scalding hazard 4 Do not connect...

Страница 21: ...to condensation pan and cause a leak and property damage 7 See pages 10 11 for complete drain line and plumbing instructions 10 The steam generator drains by gravity Plumb all drain lines accordingly...

Страница 22: ...t cable length iSteam3 Control iSteam3 BK Limited by 30 ft or 60 ft cable iSteam3 WH AirTempo Control AIRTBK Designer Code Consider wireless range maximum range is 60 ft AIRTWH Designer Code iTempo Co...

Страница 23: ...injury or death if improperly used 8 Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyp...

Страница 24: ...ng a suitable and safe steam room 17 MrSteam steam generators are intended to be operated with MrSteam controls and accessories only and are to be installed strictly in accordance with the specific in...

Страница 25: ...n before using aromatherapy Applies to 1 6 1 Use essential oils with caution Essential oils are for external use only Keep out of reach of children Essential oils are highly concentrated and are poten...

Страница 26: ...410 S La Cienega Blvd Inglewood CA 90301 TEL 1 800 72 STEAM 2020 Sussman Automatic Corporation I MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package...

Отзывы: