background image

mr

.

steam

®

 

Hydronic Towel Warmers

   

Installation and Operating Instructions

________________________________________________________________

 

11

1/2 inch

3/4 NPT

(Eccentric 

Coupling 

not used)

F lush

1/2 NPT 

Coupling 

or thread-to-sweat 

adapter to be flush 

with finished face 

of wall. 

PLUMBING PREPARATION

• If the eccentric coupling is used, a female 1/2 

NPT coupling or thread-to-sweat adapter should 
be flush with the finished face of the wall.

• If the eccentric coupling is not used a male 3/4 

NPT pipe, coupling or thread to sweat adapter 
shall be 1/2 an inch beyond the finished face of 
the wall.

HYDRONIC HOOK-UP

Hydronic Towel 

Warmer

Supplied with 
Towel Warmer

Field Supplied

Eccentric 
coupling 
(optional)

Straight 
coupling 
(or similar)

Field Plumbing

Escutcheon

Washer

Valve 
Union

STEP 3: INSTALLATION 

A. Mounting:

1. The Mr.Steam Towel Warmer has been designed with 

integral mounting brackets. These will facilitate a permanent 
and secure mounting of the Towel Warmer to the wall using 
the screws provided. 

2. Locate the brass inserts according to the following chart: 
 

    (All inlet/outlet pipes are 18 1/2” apart.)

3. Slide a bracket escutcheon (with the ‘O’ ring facing the towel  

warmer) on each of the mounting brackets.

4. Slide the towel warmer on the brass inserts and tighten the set 

screws on both brackets.  Slide the escutcheons against the 
wall to hide the joint.

5. The recommended location for optional lower brackets is on 

the bottom rung of the Towel Warmer, a sufficient header 
should be provided for these brackets.

 

 Vertical Distance from Inlet/Outlet Pipe centerline 

H542  6-7/16”

Towel 

Warmer 

Union

Washer

Valve

Содержание Fifth Avenue H542

Страница 1: ...ifth Avenue Collection Electric Hydronic Towel Warmers Models W500 W542 H542 W634 mr steam Feel Good Inc PUR 103852 REV 11 13 IMPORTANT NOTE As you follow these instructions you will notice warning an...

Страница 2: ...n precautions for your safety 1 INSTALLATION PROCEDURES FOR PERMANENTLY WIRED WALL MOUNTED UNITS MUST BE ACCOMPLISHED BY QUALIFIED PERSONNEL IN STRICT ACCORD WITH APPLICABLE NATIONAL AND LOCAL BUILDIN...

Страница 3: ...formation DO NOT install the Towel Warmer without these instructions Cover Plate Part Numbers Decorative Finishes Polished Chrome 103877PC Polished Brass 103877PB Polished Nickel 103877PN Pewter 10387...

Страница 4: ...C D W 500 22 5 8 W 542 1 1 8 2 3 4 18 1 2 243 4 W 634 1 1 8 2 3 4 143 16 2611 16 Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install prope...

Страница 5: ...rk the location where the brass inserts will be mounted to hang the towel warmer Before securing the towel warmer to the wall check to ensure the mounting points are level 6 Using the screws provided...

Страница 6: ...n on upper threaded flange as shown 4 Using the smaller allen key provided loosen the wiring box set screw DO NOT remove the wiring box 5 Rotate the wiring box as shown Tighten the set screw firmly to...

Страница 7: ...tighten the set screw firmly Secure the upper threaded flanges and lower bracket with screws provided ELECTRICAL CONNECTIONS Models W500 W542 W634 TO PREVENT SHOCK HAZARD BE CERTAIN THAT ELECTRICITY...

Страница 8: ...upply Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of PUR 103852 A Electrical connections should be made as prescribed by the National Electric and Local Codes...

Страница 9: ...t use an abrasive cleaner on the Towel Warmer A mild detergent will clean and restore most units to their original beauty 4 TO ENSURE FULL EFFICIENCY OF YOUR TOWEL WARMER PLEASE FOLLOW ALL THE INSTRUC...

Страница 10: ...Minimum Header Size 2 x 6 18 5 Inlet Outlet Pipe Center to Center 22 Min Header Length Sliding Escutcheon Set Screw Towel Warmer Header Finished surface of wall Brass Insert Screw STEP 1 PRE INSTALLAT...

Страница 11: ...Straight coupling or similar Field Plumbing Escutcheon Washer Valve Union STEP 3 INSTALLATION A Mounting 1 The Mr Steam Towel Warmer has been designed with integral mounting brackets These will facili...

Страница 12: ...Turn this union only to assemble the valve to the upright tube 1 2 Pipe field supplied Valve Washer Optional eccentric coupling supplied Do not spin this valve onto the upright tube as this may cause...

Отзывы: