background image

mr

.

steam

®

 

Electric Towel Warmers

   

Installation and Operating Instructions

________________________________________________________________

 

 WALL  PREPARATION

• DO NOT mount the Towel Warmer without 

 

providing structurally secure headers as shown.

• DO NOT mount the Towel Warmer directly to sheet

 

rock or any other non-structural surface.

• Use longer fasteners as required if the finished wall surface 

prevents adequate mounting with the screws provided.

• Provide a clearance hole in the lower header as required 

 

to route field wiring to the Towel Warmer wiring box.

If a single gang electric box has been roughed-in,  install 
cover plate PN103877. See part numbers below for decora-
tive finish information. DO NOT install the Towel Warmer 
without these instructions.

Cover Plate Part Numbers & Decorative Finishes:

Polished Chrome 

103877PC

Polished Brass  

103877PB

Polished Nickel  

103877PN

Pewter  

103877P

Satin Nickel  

103877SN

Polished Gold  

103877PG

Satin Gold 

103877SG

Antique Brass 

103877AB

Oil Rubbed Bronze  103877ORB

IMPORTANT NOTE: 

Towel Warmers may have small 

dimensional variations and must be measured prior to 
installation.

For Technical Service Assistance:
East Coast Tel: 1-800-767-8326
West Coast Tel: 1-800-727-8326
  

Lower Header (Z)

Upper Header (Z)

Lower Header (Z)

Upper Header (Z)

Wiring Box

X

Y

Wiring 

Box

Finished

wall surface

Finished

wall surface

Y

X

3

 MOUNTING DIMENSIONS

 

(inches)

For illustrative purposes only

MODEL 

X (min) 

Z (min)

 

HEADER

 

HEADER

 

HEADER

 

SIZE

 

HORIZONTAL

 

LENGTH

 

VERTICAL

 

LENGTH

W 500 

22 

5

8

 

2 x 6

W 542 

23

1

4

 

24 

3

4

 

2 x 6

W 634 

19 

27 

1

8

 

2 x 6

!

WARNING

!

CAUTION

Содержание Fifth Avenue H542

Страница 1: ...ifth Avenue Collection Electric Hydronic Towel Warmers Models W500 W542 H542 W634 mr steam Feel Good Inc PUR 103852 REV 11 13 IMPORTANT NOTE As you follow these instructions you will notice warning an...

Страница 2: ...n precautions for your safety 1 INSTALLATION PROCEDURES FOR PERMANENTLY WIRED WALL MOUNTED UNITS MUST BE ACCOMPLISHED BY QUALIFIED PERSONNEL IN STRICT ACCORD WITH APPLICABLE NATIONAL AND LOCAL BUILDIN...

Страница 3: ...formation DO NOT install the Towel Warmer without these instructions Cover Plate Part Numbers Decorative Finishes Polished Chrome 103877PC Polished Brass 103877PB Polished Nickel 103877PN Pewter 10387...

Страница 4: ...C D W 500 22 5 8 W 542 1 1 8 2 3 4 18 1 2 243 4 W 634 1 1 8 2 3 4 143 16 2611 16 Install Towel Warmers in upright position only Locate with indicator light on bottom as shown Failure to install prope...

Страница 5: ...rk the location where the brass inserts will be mounted to hang the towel warmer Before securing the towel warmer to the wall check to ensure the mounting points are level 6 Using the screws provided...

Страница 6: ...n on upper threaded flange as shown 4 Using the smaller allen key provided loosen the wiring box set screw DO NOT remove the wiring box 5 Rotate the wiring box as shown Tighten the set screw firmly to...

Страница 7: ...tighten the set screw firmly Secure the upper threaded flanges and lower bracket with screws provided ELECTRICAL CONNECTIONS Models W500 W542 W634 TO PREVENT SHOCK HAZARD BE CERTAIN THAT ELECTRICITY...

Страница 8: ...upply Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of PUR 103852 A Electrical connections should be made as prescribed by the National Electric and Local Codes...

Страница 9: ...t use an abrasive cleaner on the Towel Warmer A mild detergent will clean and restore most units to their original beauty 4 TO ENSURE FULL EFFICIENCY OF YOUR TOWEL WARMER PLEASE FOLLOW ALL THE INSTRUC...

Страница 10: ...Minimum Header Size 2 x 6 18 5 Inlet Outlet Pipe Center to Center 22 Min Header Length Sliding Escutcheon Set Screw Towel Warmer Header Finished surface of wall Brass Insert Screw STEP 1 PRE INSTALLAT...

Страница 11: ...Straight coupling or similar Field Plumbing Escutcheon Washer Valve Union STEP 3 INSTALLATION A Mounting 1 The Mr Steam Towel Warmer has been designed with integral mounting brackets These will facili...

Страница 12: ...Turn this union only to assemble the valve to the upright tube 1 2 Pipe field supplied Valve Washer Optional eccentric coupling supplied Do not spin this valve onto the upright tube as this may cause...