mr
.
steam
®
club therapy
®
Installation, Operation & Maintenance Manual
______________________________________________________________________________
2
M
Maatteerriiaallss ooff ccoonnssttrruuccttiioonn,, rroooom
m ssiizzee ((iinncclluuddiinngg rroooom
m hheeiigghhtt)) aanndd ssppeecciiaall ddeessiiggnn
ffeeaattuurreess ssuucchh aass llaarrggee ggllaassss aarreeaass,, aallll aaffffeecctt tthhee sstteeaam
m ggeenneerraattoorr m
mooddeell sseelleeccttiioonn..
1.
Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2.
Adjustments to Room Volume:
For natural stones: natural marble,
Add 100%
stone, shale, glass block or concrete
For ceramic or porcelain tile on
Add 30%
cement board or mortar bed
For each exterior wall or
Add15% each
extra glass panel
wall or panel
For each foot exceeding 8ft. in height
Add 15% each foot
3.
Add all figures above to obtain the Total Room Volume required
ROOM VOLUME
TOTAL ADJUSTED
ROOM VOLUME
SELECT YOUR MR.STEAM
Compare your TOTAL ADJUSTED ROOM VOLUME to the Specification Chart below
and select the appropriate model.
Visit www.mrsteam.com for sizing and selection calculators and additional information.
IMPORTANT:
The guidelines for selecting the steambath
generator is a recommendation only. Because of variables
in construction, these sizing instructions and specifica-
tions should be considered as guidelines only. Mr.Steam®
will review the model selected provided we receive com-
plete information, including working drawings, specifica-
tions, and pertinent electrical and construction details.
Otherwise, the manufacturer disclaims responsibility for
the sizing of a model selected.
IMPORTANT:
For steam rooms constructed of acrylic or
synthetic materials, select next lower-rated CT model.
WARNING:
In considering a purchase of this steambath
system, please note that if users are pregnant, have a coro-
nary condition, are in poor health, are being treated for
any other medical condition, or are using medication or
drugs, Mr.Steam recommends that you obtain the approval
of their physician before use. For information about this
product and safety issues, please call us at 1-800-76-STEAM
or log onto www.mrsteam.com for a copy of the
Installation/Operation/Maintenance Manual.
IMPORTANT:
The total adjusted room volume allows for up
to 60 feet of insulated steam line from the CT generator to
the steam room. If the 60 feet line is exceeded consult
with factory. When locating the steam generator consider-
ation of the control and MSTS location must be taken into
account. The maximum length for a control cable is 60
feet. The maximum length of the MSTS cable is 60 feet.
Residential Steam Generators Specification Chart
Amps (for
Total Adj
Wire
Water Usage
Shipping
Model No.
KW
240v/1PH)†
Room Vol.
Size‡
gallons††
Dimensions*
Wt. (lbs)**
CT6E
6
25
150
8
0.80
17"L x 18½"H x 7
7
⁄
8
"D
40
CT9E
9
38
360
8
1.2
17"L x 18½"H x 7
7
⁄
8
"D
40
CT12E
12
50
575
6
1.6
17"L x 18½"H x 7
7
⁄
8
"D
40
IMPORTANT: Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
IMPORTANT: All CT MS Models are cUL us Listed and CE; approved.
NOTES:
All CT Generators available in 240v/1PH, 208v/1PH and other voltages/phases.
† Amps are for 240/1PH rated units.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors.
Refer to the National Electrical Code for other types of conductors.
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator
only, without control or steamhead.
†† Water usage based on 20 minutes of operation.