background image

E-5

Forced Air Propane Construction Heater

Operating Instructions and Owner’s Manual

OPERATING INSTRUCTIONS

PREPARING FOR OPERATION

1.  Check the heater for possible shipping damage. If any is found, 

immediately

 notify the factory.

2.  Follow all of the "Precautions". 

3.  Connect the POL fitting of hose and regulator assembly to the 

propane cylinder by rotating the POL nut counterclockwise into 
the propane cylinder's valve outlet and securely tighten with a 
wrench.

4.  Connect the hose to the heater by rotating the hose fitting 

clockwise.

5.  Securely tighten all gas connections.

6.  Open the cylinder's gas valve and check all gas connections with 

a soap and water solution. DO NOT USE A FLAME.

7.  Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of 

power.

8.  When using an extension cord, make certain that it is a 3-wire 

(grounded) cord of proper wire size, minimum length of 6 ft 
(1.83m).

START

1. 

THE HEATER POWER CORD MUST BE CONNECTED TO 
A GROUNDED 115V, 60HZ, 1Ø POWER SOURCE BEFORE 
HEATER IGNITION

 and always allow heater fan (blower) to run 

for 20 seconds to purge fuel.

2.  Open propane supply valve on propane tank slowly.  Note:  If not 

opened slowly, excess-flow check valve on propane tank will stop 
gas flow.  If this happens, close propane supply valve and open 
again slowly.  Wait 15 seconds before    Step 3.

3.  Push and hold automatic control valve button.  Push piezo igniter 

button repeatedly until the burner lights.

4.  After the burner lights, keep the gas valve button depressed for 

30 seconds then release and the heater will continue to operate.

 

WARNING:

  Be sure motor and fan are running before pushing 

in automatic control valve button.  Flames could flash outside 
heater or internal damage to heater may result if motor and fan 
are not running.

STOP

1.  Securely close valve on the propane cylinder.

2.  Continue to operate heater until all fuel in the hose has burned.

3.  Unplug the power cord.

 

CAUTION:

  Always shut off fuel supply before disconnecting 

electrical power.

RESTART AFTER SAFETY SHUTDOWN

1.  Securely close valve at propane cylinder.  Unplug power cord.

2.  Wait 5 minutes. 

3.  Restart following "START" procedure.

MAINTENANCE AND STORAGE

1.  The heater should be inspected before each use, and at least 

annually by a qualified person.

2.  Before each use, check the soft "O" ring seat at the bullnose 

of the POL fitting. If the "O" ring is cut, scuffed, or otherwise 
damaged, replace it with part number 6681.

3.  Turn off the gas at the LP-gas supply cylinder(s) when the heater 

is not in use.

4.  When the heater is to be stored indoors, the connection 

between the LP-gas supply cylinder(s) and the heater must 
be disconnected and the cylinder(s) removed from the heater 
and stored out of doors and in accordance with Chapter 5 of 
the standard for Storage and Handling of Liquefied Petroleum 
Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane 
Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has been 
modified or is not functioning properly. When the heater is working 
properly:

The flame is contained within the heater.

*   The flame is essentially blue with perhaps some yellow tipping.

There is no strong disagreeable odor, eye burning or other 
physical discomfort.

There is no smoke or soot internal or external to the heater.

There are no unplanned or unexplained shut downs of the 
heater.

The parts lists and exploded view show the heater as it was 
constructed. Do not use a heater which is different from that shown. 
In this regard, use only the hose, regulator and cylinder connection 
fitting (called a POL fitting) supplied with the heater. 

IMPORTANT

 

Match the color stripe on the hangtag attached to the hose assembly 
with the color on the label located near the propane inlet fitting on 
the heater. Do not use alternates. For this heater, the regulator must 
be set as shown in "specifications". If there is any uncertainty about 
the regulator setting, have it checked.

A heater which is 

not 

working right must be repaired, but 

only

 by a 

trained, experienced service person.

In-warranty products will be repaired with no charge for either parts 
or labor. Please include a brief statement indicating date, place of 
purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts and 
labor.

   

Содержание MH35FA

Страница 1: ...open flame Shut off gas to appliance Service must be performed by a qualified service agency This is an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequat...

Страница 2: ...ANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNE...

Страница 3: ...the heater thoroughly for damage DO NOT operate a damaged heater 2 DO NOT modify the heater or operate a heater which has been modified from its original condition 3 Use only propane gas 4 Use only VA...

Страница 4: ...son and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must repair any leaks check for further leakages and then relig...

Страница 5: ...nder Unplug power cord 2 Wait 5 minutes 3 Restart following START procedure MAINTENANCE AND STORAGE 1 The heater should be inspected before each use and at least annually by a qualified person 2 Befor...

Страница 6: ...1 21 72801 base assembly qbt 38k 1 22 72805 base panel bottom 38k 1 23 27956 hose and regulator assembly 1 REF ITEM DESCRIPTION QTY 1 72813 guard rear qbt 38k 1 2 72803 spacer fan qbt 38k 4 3 27943 fa...

Страница 7: ...cooperation of independent dealers a nationwide network of authorized servicing dealers is available for your servicing requirements Should your product require servicing read the section of the manu...

Страница 8: ...other warranties express or implied Specifically there is no warranty of fitness for a particular purpose and there is no warranty of merchantability In no event shall the Company be liable for delay...

Страница 9: ...on en gaz l appareil L entretien doit tre effectu par un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif aliment au gaz n est pas ventil Il utilise l oxyg ne de l air am...

Страница 10: ...L APPAREIL DE CHAUFFAGE DANS UN ENDROIT QUI CONTIENT OU RISQUE DE CONTENIR DES COMBUSTIBLES VOLATILES OU EN SUSPENSION DANS L AIR OU DES PRODUITS TELS QUE DE L ESSENCE DES SOLVANTS DU DILUANT PEINTUR...

Страница 11: ...er un appareil endommag 2 NE MODIFIEZ PAS l appareil de chauffage et ne le faites pas fonctionner s il n est plus dans son tat d origine 3 Utilisez uniquement du gaz propane 4 Utilisez uniquement une...

Страница 12: ...mporte aucun risque EN DERNIER LIEU laissez le personnel du service des incendies ou d approvisionnement en gaz combustible v rifier si du gaz s chappe Assurez vous qu ils aient a r l immeuble avant d...

Страница 13: ...oujours l alimentation en gaz avant de d brancher l alimentation lectrique RED MARRAGE APR S UN ARR T D URGENCE 1 Fermez compl tement le robinet sur la bonbonne de gaz propane D branchez le cordon d a...

Страница 14: ...r leur assemblage principal 35 k 38 k 1 8 27935 interrupteur sup rieur limite 1 9 72815 support flamme assemblage 35 k 1 10 27925 poign e transport plastique 1 11 72816 cran radiation assemblage 35 k...

Страница 15: ...pour r pondre vos besoins en mati re de r paration Si ce produit n cessite des r parations lisez la section R paration du pr sent manuel qui s adresse la garantie Seul l acheteur original du produit...

Страница 16: ...nt l ad quation une utilisation particuli re ni aucune garantie concernant la qualit marchande En aucun cas l entreprise ne saura tre tenue responsable des retards caus s par des d fectuosit s ni des...

Страница 17: ...istro de gas al artefacto El mantenimiento debe ser realizado por una agencia de reparaci n calificada Este calentador port til a gas no tiene una fuente propia de ventilaci n Utiliza el aire ox geno...

Страница 18: ...DE CONSTRUCCI N PAPEL O CART N A UNA DISTANCIA SEGURA DEL CALENTADOR TAL COMO LO RECOMIENDAN LAS INSTRUCCIONES NUNCA USE EL CALENTADOR EN ESPACIOS QUE CONTIENEN O PODR AN CONTENER COMBUSTIBLES VOL TIL...

Страница 19: ...os NO use un calentador da ado 2 NO modifique el calentador ni lo use si su configuraci n original ha sido modificada 3 Utilice nicamente gas propano 4 Utilice nicamente suministro de propano con REC...

Страница 20: ...POR LTIMO permita que la persona del servicio de gas y los bomberos revisen si hay fugas de gas Haga que ventilen el edificio y el rea antes de su regreso Un agente de servicios calificado debe repar...

Страница 21: ...enchufe el cable de alimentaci n 2 Espere 5 minutos 3 Reinicie seg n se indica en la secci n sobre el procedimiento de ENCENDIDO MANTENIMIENTO Y ALMACENAMIENTO 1 Debe inspeccionar el calentador antes...

Страница 22: ...conj principal 35 k 38 k 1 8 27935 interruptor m ximo limitador 1 9 72815 sost n llama conj 35 k 1 10 27925 mango transporte pl stico 1 11 72816 protecci n radiaci n conj 35 k 1 12 72810 tanque qbt 38...

Страница 23: ...es de reparaci n Si su producto necesitara mantenimiento lea la secci n del manual titulada Mantenimiento A qui n le corresponde la garant a La garant a se limita al consumidor que realiz la compra or...

Страница 24: ...responsabilidades de la Compa a en toda su extensi n No hay otras garant as ni expl citas ni impl citas Espec ficamente no hay garant as acerca de la adecuaci n para un prop sito particular y no hay...