background image

INSTALLATION INSTRUCTIONS
GENERAL:

READ THESE INSTRUCTIONS CAREFULLY. Read and adhere
to these instructions. DO NOT allow anyone who has not
read these instructions to assemble, light, adjust or operate
this heater.

DO NOT attempt to operate the heater with any gas other
than that indicated on the heater nameplate.

For the U.S. and/or Canada, the installation of this appliance
must comply with local and/or Provincial codes or, in the
absence of these codes,

With the (U.S.) National Fuel Gas Code, ANSI Z223.1 –
Latest Edition (for Natural and LP-Gas operation,
Models HS125NG, MH125LP, and HS125LP), and with
the (U.S) Standard for the Storage and Handling of
Liquefied Petroleum Gases, ANSI/NFPA 58 (for LP Gas
operation, Model MH125LP, HS125LP), or

with the current (Canadian) CAN/CGA B149.1 AND
B149.2 INSTALLATION CODES.

This heater (including hose and regulator assembly if applicable)
must be inspected before each use and at least annually by a
qualified service person. If the hose for Model MH125LP/HS125LP
shows evidence of excessive abrasion or wear, or if the hose is
cut, it must be replaced prior to the heater being put into
operation. The replacement hose assembly shall be that specified
by the manufacturer. See the parts list.

LOCATION

The heater (and LP-Gas supply cylinder if applicable) must be
located on a hard, flat, level surface to minimize the risk of
accidental tipping. If an LP Gas supply cylinder is used (i.e. with
Model MH125LP/HS125LP), the cylinder should be adequately
restrained to prevent accidental tipping. 

DO NOT operate this

heater with the supply cylinder in any other than the
upright position.

This appliance must be installed only in locations where the
potential for physical damage to the appliance (i.e., due to
physical contact) is reduced to a minimum.

The installer must inform the owner/operator of this appliance
that precautions must be taken to protect the appliance from
physical damage.

This appliance produces radiant heat. Therefore, it must be
located at least six feet away from any LP-Gas container and
must not be directed toward any LP-Gas container within 20 feet.

The heater must be installed in a location such that it will not be
exposed directly to water spray, rain, and/or dripping water.

Use of this heater in a draft/windy area decreases its efficiency.
If possible, operate the unit in a draft free area.

PIPING

For Model MH125LP/HS125LP
(for use with LP-Gas)

This model may be connected to a self-contained LP-Gas
supply system using the hose and regulator assembly
supplied with the appliance, OR, it may be connected to a
permanently installed LP-Gas supply system.

If connected to a self-contained LP-Gas supply system, the
hose assembly must be inspected prior to each use of the
heater. If it is evident that there is excessive abrasion or
wear, or if the hose is cut, it must be replaced prior to the
heater being put into operation.

If connected to a self-contained LP-Gas supply system, the
cylinder must have no less than a minimum capacity of 20
pounds and no more than a maximum capacity of 100
pounds of LP-Gas. DO NOT connect this appliance to a
cylinder having less than a nominal 20 pounds capacity of
LP-Gas. DO NOT connect this appliance to more than one
(1) 100 pound cylinder.

WARNING

NEVER USE A FORK LIFT TRUCK TYPE
CYLINDER.

The connection of Model MH125LP/HS125LP to an LP-Gas
cylinder must be made in a well ventilated area using the
regulator and hose assembly supplied with the appliance. 

DO

NOT attempt to adjust this regulator.

 It has been preset at

the factory to provide safe and proper operation of the
appliance. Use a 7/8” open end wrench to connect the POL
fitting (supplied with the LP regulator) to the LP-Gas cylinder.
Turn the POL nut in a counter-clockwise direction (left hand
thread) until tight. 

DO NOT use pipe compound

on POL threads.

The heater must be located at least six feet away from any
LP-Gas cylinder and must not be directed toward any LP-Gas
cylinder within 20 feet. If more than one heater is used,
they and the supply cylinders must be separated by at least
20 feet.

The gas supply must be turned off at the LP-Gas supply
cylinder when the heater is not in use.

When the heater is to be stored indoors, the connection
between the LP-Gas supply cylinder and the heater must be
disconnected and the cylinder removed from the heater and
stored in accordance with Chapter 5 of the Standard for the
Storage and Handling of Liquefied Petroleum Gases. ANSI/
NFPA 58 (U.S.) OR CAN/CGA B149.2 (Canada).

If connected to a permanently installed LP-Gas supply
system, the system requires the use of a two-stage gas
regulator assembly which is normally provided by your LP
Gas dealer as part of the LP-Gas supply system. Consult
with your local LP Gas dealer for details concerning proper
equipment and installation.

3

Operating Instructions and Owner’s Manual

Enerco Group, Inc. | Gas-Fired Infra-Red Portable Construction Heater

Содержание HS125LP

Страница 1: ...R IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS INSTRUCTION MANUALS LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODU...

Страница 2: ...red or used WARNING DO NOT EXCEED psi 14 w c GAS PRESSURE TO THE GAS CONTROL VALVE SPECIFICATIONS MODEL NO MH125LP HS125LP HS125NG GAS TYPE LP Gas Natual Gas MAX INLET PRESSURE 14 IN W C 14 IN W C MIN INLET PRESSURE 1 1 IN W C 7 IN W C MANIFOLD PRESSURE 9 5 IN W C 6 IN W C VENTILATION WARNING THIS APPLIANCE IS UNVENTED AND MUST BE USED ONLY IN A WELL VENTILATED AREA The flow of combustion and vent...

Страница 3: ...IPING For Model MH125LP HS125LP for use with LP Gas This model may be connected to a self contained LP Gas supply system using the hose and regulator assembly supplied with the appliance OR it may be connected to a permanently installed LP Gas supply system If connected to a self contained LP Gas supply system the hose assembly must be inspected prior to each use of the heater If it is evident tha...

Страница 4: ...mell next to the floor because LP Gas is heavier than air and will settle on the floor Turn on the gas supply to the appliance and check all fittings and connections for gas leaks using a mild soap and water solution NEVER use a match to check for gas leaks Should a gas leak occur shut off the gas supply to the appliance immediately Wait a minimum of five minutes before repairing the leak 2 Use on...

Страница 5: ... must be replaced prior to the heater being put into operation The replacement hose assembly shall be that specified by the manufacturer See the parts list The appliance area must be kept free and clear of combustible materials gasoline and other flammable vapors and liquids at all times The flow of combustion and ventilation air must not be obstructed Cleaning the heater Periodically the heater m...

Страница 6: ...1 1357 Pilot Burner 6 1 1663 Regulator MH125LP HS125LP 7 1 1666 Regulator HS125NG 8 05374 Orifice Pilot HS125NG 9 CR805 Ignitor 10 CR835 Piezo 1 1 CR820 Axle 12 CR815 Axle Brackets 13 CR725 Handle 14 CR810 Wheel 15 M9005 Valve Supply Tube 16 M9010 Valve Supply Tube Clamp 17 M9015 Burner Manifold 18 M9020 Burner Figure 2 Figure 1 6 Operating Instructions and Owner s Manual Enerco Group Inc Gas Fire...

Страница 7: ...G MH125LP HS125LP 4 3 2 1 5 6 7 8 9 10 11 12 13 14 Combustion Chamber Mounting Bracket Pilot Supply Tube Propane Hose Top Plate Frame Assembly 15 16 17 18 7 Operating Instructions and Owner s Manual Enerco Group Inc Gas Fired Infra Red Portable Construction Heater ...

Страница 8: ...to replace or repair any part for which a written claim is made to Enerco Group Inc within the time limit of this warranty which is returned upon request to Enerco Group Inc F O B Cleveland Ohio or F O B an Enerco Group Inc authorized service facility and which is proved to be defective upon inspection by Enerco Technical Products This warranty shall not apply to any part or product which has been...

Страница 9: ...remplacer ou de réparer toute pièce défectueuse pour laquelle une réclamation a été écrite à l attention d Enerco Group Inc et après qu Enerco Group Inc a confirmé sa défectuosité et ce dans la période de temps stipulée par la garantie laquelle doit être retournée sur demande à Enerco Group Inc par franco à bord à Cleveland Ohio ou franco à bord à toute installation de service autorisée par Enerco...

Страница 10: ...5LP 4 3 2 1 5 6 7 8 9 10 11 12 13 14 Chambre de combustion Support de fixation Tube d alimentation de la veilleuse Tuyau pour gaz propane Plateau supérieur Structure 7 Enerco Group Inc Appareil de chauffage portatif à infrarouge et au gaz Manuel de l utilisateur et instructions d utilisation 15 16 17 18 ...

Страница 11: ...ermocouple 5 1 1357 Brûleur de la veilleuse 6 1 1695 Régulateur MH125LP HS125LP 7 1 1666 Régulateur HS125NG 8 05374 Orifice de la veilleuse HS125NG 9 CR805 Allumeur 10 CR835 Piezo 1 1 CR820 Essieu 12 CR815 Tige de l essieu 13 CR725 Poignée 14 CR810 Roue 15 M9005 Valve Supply Tube 16 M9010 Valve Supply Tube Clamp 17 M9015 Burner Manifold 18 M9020 Burner Figure 2 Figure 1 6 Enerco Group Inc Appareil...

Страница 12: ...coupé remplacez le avant de mettre l appareil de chauffage en marche La tuyauterie de remplacement doit avoir été approuvée par le fabricant Voir la liste des pièces de remplacement L espace environnant de l appareil doit toujours être dépourvu de combustibles d essence ou de vapeurs ou de liquides inflammables La circulation d air et le flux de combustion ne doivent pas être ralentis Nettoyage L ...

Страница 13: ...st important de sentir au niveau du sol Alimentez l appareil en gaz et inspectez les joints pour détecter toute fuite de gaz à l aide d eau savonneuse N UTILISEZ JAMAIS une flamme nue pour détecter une fuite En cas de fuite couper immédiatement l alimentation en gaz à l appareil Attendez au moins 5 minutes avant de colmater la fuite 2 Utilisez seulement le type de combustible prévu pour le présent...

Страница 14: ...pane liquéfié Ce modèle peut être branché à un système d alimentation autonome de gaz propane liquéfié à l aide du tuyau et de l ensemble de régulation fournis avec l appareil OU peut être branché à un système d alimentation de gaz propane liquéfié installé de façon permanente Si branchée à un système d alimentation autonome de gaz propane liquéfié la tuyauterie doit être examinée avant chaque uti...

Страница 15: ...N EXCÉDEZ PAS PSI 14 POUCES D EAU DE PRESSION À LA VALVE D ADMISSION DU GAZ SPÉCIFICATIONS N O DE MODÈLE MH125LP HS125LP HS125NG TYPE DE GAZ Gaz propane liquéfié Gaz naturel PRESSION D ADM MAX 14 PO D EAU 14 PO D EAU PRESSION D ADM MIN 11 PO D EAU 7 PO D EAU PRESSION D ADMISSION 9 5 PO D EAU 6 PO D EAU VENTILATION MISE EN GARDE LE PRÉSENT APPAREIL N EST PAS VENTILÉ ET DOIT ÊTRE UTILISÉ SEULEMENT D...

Страница 16: ...PAREIL COMME DES MODES D EMPLOI DES ÉTIQUETTES ETC VEUILLEZ COMMUNIQUER AVEC LE FABRICANT MISE EN GARDE RISQUE D INCENDIE DE BRÛLURE D INHALATION DE SUBSTANCES TOXIQUES ET D EXPLOSION TEL QUE MENTIONNÉ DANS LE MANUEL DE L UTILISATEUR VEUILLEZ GARDER LES COMBUSTIBLES SOLIDES TELS QUE LES MATÉRIAUX DE CONSTRUCTION LE PAPIER OU LE CARTON À DISTANCE DE L APPAREIL DE CHAUFFAGE N UTILISEZ JAMAIS L APPAR...