background image

Enerco Group, Inc. | Force-Air Natural Gas Construction Heater

Operating Instructions and Owner’s Manual

8

wARNING: 

USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE 

OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS 
ARE ONLY AVAILABLE DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY 
A QUALIFIED SERVICE AGENCY. 

pARTS ORDERING INFORMATION:

pURCHASING: 

Accessories may be purchased at any Mr. Heater/HeatStar local dealer 

or direct from the factory 

FOR INFORMATION REGARDING SERVICE

Please call Toll-Free 800-251-0001 • www.enerco-mrheater.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday. 
Email to: [email protected]
Please include the model number, date of purchase, and description of problem in all 
communication.

LIMITED wARRANTY

 

The company warrants this product to be free from imperfections in material or workmanship, 
under normal and proper use in accordance with instructions of The Company, for a period of 
one year from the date of delivery to the buyer. The Company, at its option, will repair or replace 
products returned by the buyer to the factory, transportation prepaid within said one year period 
and found by the Company to have imperfections in material or workmanship. 

If a part is damaged or missing, call our Technical Support Department at 800-251-0001. 

Address any Warranty Claims to the Service Department, Enerco Group, Inc., 4560 W. 160th St., 
Cleveland, Ohio 44135. Include your name, address and telephone number and include details 
concerning the claim. Also, supply us with the purchase date and the name and address of the 
dealer from whom you purchased our product. 

The foregoing is the full extent of the responsibility of the Company. There are no other 
warranties, express or implied. Specifically there is no warranty of fitness for a particular purpose 
and there is no warranty of merchantability. In no event shall the Company be liable for delay 
caused by imperfections, for consequential damages, or for any charges of the expense of 
any nature incurred without its written consent. The cost of repair or replacement shall be the 
exclusive remedy for any breach of warranty. There is no warranty against infringement of the 
like and no implied warranty arising from course of dealing or usage of trade. This warranty will 
not apply to any product which has been repaired or altered outside of the factory in any respect 
which in our judgment affects its condition or operation. 

Some states do not allow the exclusion or limitation of incidental or consequential damages, so 
the above limitation or exclusion may not apply to you. This Warranty gives you specific legal 
rights, and you may have other rights which vary from state to state.

Enerco Group, Inc.,

 reserves the right to make changes at any time, without notice or 

obligation, in colors, specifications, accessories, materials and models.

ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-881-5500
Mr. Heater is a registered trademarks of Enerco Group, Inc.
© 2004, Enerco Group, Inc. All rights reserved

ANSI Z83.7/CGA 2.14-2000

®

®

READ INSTRUCTIONS CAREFULLY:

 Read and follow all instructions. 

Place instructions in a safe place for future reference. Do not allow any-
one who has not read these instructions to assemble, light, adjust or 
operate the heater.

HS170

NG

M

ODEL

OpERATING INSTRUCTIONS AND OwNER’S MANUAL

HEATSTAR

70101   Rev. C   04/08

Содержание 150FATNG

Страница 1: ...an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to page 3 READ INSTRUCTIONS CAREFULLY Read and...

Страница 2: ...DBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOL...

Страница 3: ...is responsible for properly acquainting those present with the safety precautions and instructions and of the hazards involved SAFETY PRECAUTIONS 1 Check the heater thoroughly for damage DO NOT opera...

Страница 4: ...ent of gas through the soil can filter the odorant ODOR FADE WARNING WARNING Asphyxiation Hazard Do not use this heater for heating human living quarters Do not use in unventilated areas The flow of c...

Страница 5: ...until all fuel in the hose has burned 3 Turn the heater thermostat to off For extended shutdown or in areas where the temperature is below 0 F unplug the heater RESTART AFTER SAFETY SHUTDOWN 1 Secure...

Страница 6: ...chart below Recommended Minimum Gauge for Cord Extensions Wire Gauge Chart A W G Name Plate 120V Cord Length in Feet Amps 25 50 100 150 5 6 18 16 14 12 6 8 18 16 12 10 8 12 18 14 12 10 10 12 16 14 10...

Страница 7: ...7 Enerco Group Inc Force Air Natural Gas Construction Heater Operating Instructions and Owner s Manual...

Страница 8: ...the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty...

Страница 9: ...Ce qui est nonc ci dessus constitue la responsabilit totale de l entreprise Il n existe aucune autre garantie expresse ou tacite Plus pr cis ment il n y a aucune garantie concernant l ad quation une u...

Страница 10: ...Guide d utilisation et instructions de fonctionnement Enerco Group Inc Appareil de chauffage air puls au gaz propane pour chantier de construction 7...

Страница 11: ...t tre tablie l aide du tableau ci dessous Calibre minimum recommand pour rallonges Tableau de calibre de c ble AWG Plaque d identification Longueur de la rallonge en pieds 120 V A 25 50 100 150 5 6 18...

Страница 12: ...r gions o la temp rature est inf rieure 17 8 C 0 F d branchez le cordon d alimentation de l appareil de chauffage RED MARRAGE APR S UN ARR T D URGENCE 1 Fermez compl tement le robinet sur la bonbonne...

Страница 13: ...uelconque peut s estomper si vous AVERTISSEMENT RELATIF AUX SUBSTANCES ODORANTES AVERTISSEMENT Risque d asphyxie Cet appareil ne doit pas tre utilis pour le chauffage de locaux o demeurent des gens Ne...

Страница 14: ...appareil de chauffage doit fonctionner en pr sence d autres personnes l utilisateur est responsable d informer ces derni res des instructions et pr cautions li es la s curit et de les avertir des dan...

Страница 15: ...COMME LE RECOMMANDENT LES INSTRUCTIONS N UTILISEZ JAMAIS L APPAREIL DE CHAUFFAGE DANS UN LOCAL QUI CONTIENT OU RISQUE DE CONTENIR DES PARTICULES COMBUSTIBLES EN SUSPENSION DANS L AIR OU DES PRODUITS...

Страница 16: ...toute flamme nue Fermez l alimentation en gaz l appareil L entretien doit tre effectu par un fournisseur de services d entretien qualifi Cet appareil de chauffage portatif aliment au gaz n est pas ve...

Отзывы: