8.3 Load indicator

Indicator status

Off

Steady on

Quick flash (on for 0.1s, off for 0.1s, a cycle of 0.2s)

Load status

Load has been turned off

Load output is normal

Overload/short circuit

8.4 Fault indicator

Indicator status

Off

Steady on

 Fault status

System is normal

System failure

9. Menu Display

9.1 Menu diagram

9.2 Menu display

10. Error Codes

LCD 

E0

E1

E2

E3

E4

E5

E6

E7

E8

E10

E13

E15

Description

System is normal

Battery over-discharge 

Battery over-voltage, battery icon 
indicator flashing fast

Battery under-voltage warning

Load short circuit

Load over current

Controller internal over temperature

Battery charge over temperature 
protection

Solar panel input power excessive, 
charge over current

Solar panel over voltage

Solar panel reverse polarity

Battery not connected or lithium 
battery feed

Controller action

No action

Turn off load output; when the battery voltage rises to the 

over discharge return voltage, the over discharge is removed, 

and the load output resumes

Turn off charging; check the cause of battery over voltage, 
and when voltage drops, charging automatically resumes
The battery voltage is lower than the under-voltage warning 
threshold. Only alert is given, with no action

Turn off load output

Delay to turn off load at multiples of rated current

The internal temperature of controller is too high, MPPT 
controller starts charging with reduced power; when the 
temperature is below a certain value, charging automatically 
resumes
Turn off charging, and it will automatically resume when 
the temperature is below a certain value

MPPT controller charges with limited current

Solar panel over voltage; turn off charging, and it will 
automatically resume when the temperature is below the 
safety value

Turn off charging and discharging

As long as the solar panel voltage meets the charging 
conditions, the lithium battery has constant voltage 
output, and the lead-acid battery has no voltage output, 
this error returns to normal after battery is connected

8.2 Battery indicator

Indicator status

Steady on

Slow flash (on for 1s, off for 1s, a cycle of 2s)

Quick flash (on for 0.1s, off for 0.1s, a cycle of 0.2s)

Battery status

Battery is normal

Battery over-discharge

Battery over voltage

13

14

System 
voltage

Battery type

Battery indication

Load output indication 

Charging 

indication

Solar panel 

indication

Day indication

Night 

indication

Charge 

stage 

indication

Unit display 
area

Setting 

indication

Communication 

indication

Abnormal indication

Parameter 
display area

12V/24V/36V/48V

12V

Main screen

Solar panel voltage

Charge current

Charge power

Charge AH

Load

 

current

Load

 

power

Discharge AH

Load mode

Device temperature

Error

 

code

Содержание 104714

Страница 1: ...User Manual MPPT Solar Charge and Discharge Controller Mode 104714...

Страница 2: ...risk of heat build up due to poor contact WARNING Indicates that this operation is dangerous and that safety precautions must be taken prior to the operation Caution Indicates that this operation is d...

Страница 3: ...lar panel cathode interface Battery anode interface Battery cathode interface Load anode interface Load cathode interface Temperature sensor interface Name RS485 isolated communication interface Charg...

Страница 4: ...stop bit1 no check bit default address 1 Natural heat dissipation heat dissipation by fan By RS485 communication cables multiple controllers can work in parallel to control charging For battery tempe...

Страница 5: ...of sensitive DC loads It is therefore necessary to verify that the allowable input voltage for all loads in the system is greater than the set value for battery equalizing charge 3 Overcharging and to...

Страница 6: ...urning and then the backlight is always on Menu auto page turning each page stays for 3 seconds and the setting will not be saved when power off When a button is pressed the system immediately exits t...

Страница 7: ...is 5 minutes by default the load is turned on After the working time reaches the set value light and time control time the load is turned off When sunlight comes out before the light and time control...

Страница 8: ...y to turn off load at multiples of rated current The internal temperature of controller is too high MPPT controller starts charging with reduced power when the temperature is below a certain value cha...

Страница 9: ...wires when the system is moved The voltage at the output terminals may exceed the human safety voltage when connecting the system so use insulated tools and keep your hands dry The battery terminals o...

Страница 10: ...epair or replace Check for exposed damaged insulation performance deteriorated wires which should be timely repaired or replaced Check for dirt nesting insects and corrosion and if so clean up in time...

Отзывы: