4-63. CONVERSION FROM G2 TO G3
To convert a Moyno 2000 Pump from G2 to G3 construc-
tion requires that the top of the bearing housing (14,
fig. 4-7) be machined flat and that two drilled and tapped
holes be added for mounting the bridge breaker bearing
support.
This can be done internally or at a local machine shop fol-
lowing the dimesional data shown in fig. 4-9. Alter-
nately, a G3 bearing housing (Ref. No. 34
⎯
Section 4-62)
may be ordered.
Figure 4-9. Bearing housing machining to convert
G2 to G3.