NPort IA5000A Series
Web Console Configuration
5-19
Command port
Setting
Factory Default
Necessity
1 to 65535
966
Optional
The “Command port” is a listening TCP port that received IP-Serial Lib commands from the host. In order to
prevent a TCP port conflict with other applications, the user can set the Command port to another port as
needed. IP-Serial Lib will automatically check the Command Port on the NPort IA5000A so that users do not
need to configure the program.
TCP Client Mode
TCP alive check time
Setting
Factory Default
Necessity
0 to 99 min
7 min
Optional
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min: The NPort IA5000A automatically closes the TCP connection if there is no TCP activity during this
given time.
Inactivity time
Setting
Factory Default
Necessity
0 to 65535 ms
0 ms
Optional
0 ms: TCP connection is not closed due to an idle serial line.
0-65535 ms: The NPort IA5000A automatically closes the TCP connection if there is no serial data activity
during the given time.