NPort 5000 Series User Manual
93
Pair Connection Slave Mode
When using Pair Connection Mode, you must select
Pair Connection Slave Mode
for the Operation mode
of one of the NPort device servers. In effect, this NPort will be acting as a TCP server.
Web Interface for the NPort 5100, 5200, and IA5000 Series Only
Web Interface for the Overall NPort 5000 Series
Parameter
Setting
Factory
Default
Description
Necessity
TCP Alive
Check Time
0 to 99 min
7 min
0 min:
TCP connection is not closed due to an
idle TCP connection.
1 to 99 min:
The NPort closes the TCP
connection automatically if there is no TCP
activity for the given time.
Required
Local TCP port
TCP port No.
(e.g.,
4001)
4001
This Port No. must be the same port No. that
you set up for the Pair Connection “Master”
device server.
Required