Moxa MxNVR Industrial Video Recorder
System Configuration
5-31
Alarm
System Alarm
In addition to the LED indicators, three kinds of system alarms are provided by the MxNVR-MO4 364 for
notifying the system operations administrator.
Alarm Type
Triggered Condition
Triggered Action
Network Disconnected
Network disconnected
Relay
Network Disconnected Alarm
Setting
Description
Default
Enable network
disconnected alarm
Enable or disable network disconnected alarm.
Disable
Trigger Relay alarm
Enable or disable the triggering of Relay 1 or Relay 2 alarms. Disable
NOTE
Since several alarms can be set up to trigger the MxNVR-MO4’s relays, the administrator should configure
these alarms carefully in case a relay message is read incorrectly.
Event Alarm
Four kinds of event alarm are provided by the MxNVR-MO4 for building an intelligent video surveillance system.
Alarm Type
Triggered Condition
Triggered Action
Video Motion Detection (VMD)
VMD 1
VMD 2
VMD 3
1.Relay
2.Email
3.FTP
4.HTTP Event Server
5. Record video on HDD
Digital Inputs
DI 1
DI 2
1.Relay
2.Email
3.FTP
4.HTTP Event Server
5. Record video on HDD
Video Loss
Video signal is lost
1.Relay
2.Email
3.HTTP Event Server
CGI Event
The CGI trigger message
1.Relay
2.Email
3.FTP
4.HTTP Event Server
5. Record video on HDD
Sequential Snapshot
Enable sequential snapshot
Email
FTP