- 7 -
STEP 3:
Once the screws are fixed
on the wall, insert the four screw
heads through the large parts of the
keyhole-shaped apertures, and then
slide the EDS downwards, as
indicated. Tighten the four screws
for added stability.
Grounding the INJ-24A
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel.
Wiring the INJ-24A’s Power Outputs
The 4-contact terminal block connector on the INJ-24A’s top panel is used
for dual 24/48 VDC power inputs. Top and front views of the terminal
block connectors are shown here.
STEP 1:
Insert the negative/positive DC wires into the V-/V+
terminals.
STEP 2:
To keep the DC wires from pulling loose, use a small
flat-blade screwdriver to tighten the wire-clamp screws on
the front of the terminal block connector.
STEP 3:
Insert the plastic terminal block connector prongs
into the terminal block receptor, which is located on the
INJ-24A’s top panel.
NOTE
Both V1+ and V2+ are internally connected. Incorrect cabling
may cause device damage.