background image

 

- 10 - 

 

Environmental Limits

 

Operating Temperature  Standard Models: 0 to 60°C (32 to 140°F)   

Wide Temp. Models: -40 to 75°C (-40 to 167°F) 

Storage Temperature 

-40 to 85°C (-40 to 185°F) 

Ambient Relative 
Humidity 

5 to 95% (non-condensing) 

Regulatory Approvals

 

EMI 

FCC Part 15, CISPR (EN 55022) class A 

EMS 

EN 61000-4-2 (ESD), Level 3   
EN 61000-4-3 (RS), Level 3   
EN 61000-4-4 (EFT), Level 3   
EN 61000-4-5 (Surge), Level 3   
EN 61000-4-6 (CS), Level 3 
EN 61000-4-8, Level 5 

Shock 

IEC 60068-2-27 

Freefall 

IEC 60068-2-32 

Vibration 

IEC 60068-2-6 

Warranty

 

Time Period 

5 years 

Details 

www.moxa.com/warranty   

 
 
 
 
 
 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Содержание INJ-24A Series

Страница 1: ...2012 Moxa Inc All rights reserved P N 1802000240020 Moxa High Power PoE Injector INJ 24A Series Hardware Installation Guide First Edition October 2012...

Страница 2: ...ess APs and IP cameras which only have 4 pins in the cable In addition the INJ 24A can resist 3KV surges from the PoE port protecting system operations in critical industrial environments and complies...

Страница 3: ...nal characteristics should be routed separately You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares...

Страница 4: ...to 75 C for T models IP30 rugged high strength case DIN Rail or panel mounting ability Panel Layout 1 Terminal block for P1 P2 power inputs 2 Power input P1 LED 3 Power input P2 LED 4 10 100 1000BaseT...

Страница 5: ...5 Mounting Dimensions unit mm...

Страница 6: ...wn in the following figures STEP 1 Remove the aluminum DIN rail attachment plate from the INJ 24A s rear panel and then attach the wall mount plates as shown in the diagram to the right STEP 2 Mountin...

Страница 7: ...ounded mounting surface such as a metal panel Wiring the INJ 24A s Power Outputs The 4 contact terminal block connector on the INJ 24A s top panel is used for dual 24 48 VDC power inputs Top and front...

Страница 8: ...t standard devices Std PoE 30 watts Hi PWR 36 watts 2 Hi PWR ON The INJ 24A is set to support high power output 36 watts Std PoE OFF The INJ 24A only provides standard PoE power output 802 3af 15 4 wa...

Страница 9: ...with a 2 pair mode PD the 802 3af at LED will always be green Specifications Technology Standards IEEE 802 3 802 3u 802 3ab 802 3af 802 3at Interface RJ45 Ports 10 100 1000BaseT X speed LED Indicator...

Страница 10: ...vel 3 EN 61000 4 5 Surge Level 3 EN 61000 4 6 CS Level 3 EN 61000 4 8 Level 5 Shock IEC 60068 2 27 Freefall IEC 60068 2 32 Vibration IEC 60068 2 6 Warranty Time Period 5 years Details www moxa com war...

Отзывы: