Pinouts and Cable Wiring
l
l
Appendix A
45
A.3 RS-485
The pinouts of the RS-485 port are the same as RS-422 except that only TxD+,
TxD-, RxD+, RxD- and GND are used. The following lists pinouts of the RS-422
port.
C114HI DB-9 Male Connector
C114HI Pin-head Connector
1
TxD-(A)
1
TxD-(A)
2
RxD+(B)
2
RxD+(B)
3
TxD+(B)
3
TxD+(B)
4
RxD-(A)
4
RxD-(A)
5
GND
5
GND
There are two operation modes for RS-485. Note that when jumper set to half
duplex, TxD+ with RxD+ and TxD- with RxD-
are shorted internally on board
.
Only TxD+ and TxD- are good for connection.
1. Point-to-Point
Point-to-Point configuration means two devices located at two different places
can be linked together to communicate via RS-485 interface.
Point-to-Point RS-485 Half-Duplex
Point-to-Point RS-485 Full-Duplex
C114HI
Remote site
C114HI
Remote site
1
TxD-
RxD-
1
TxD-
RxD-
4
RxD-
TxD-
4
RxD-
TxD-
3
TxD+
RxD+
3
TxD+
RxD+
2
RxD+
TxD+
2
RxD+
TxD+
5
GND
GND
5
GND
GND
4
3
2
1
5
9
8
7
6
10
GND
RxD-
TxD+
RxD+
TxD-
9
8
7
6
G
Rx
Tx
Rx
Tx
5
4
3
2
1
Содержание Industio C114HI
Страница 1: ...C114HI 3 in 1 RS 232 422 485 Industrial Serial Board Apr 1998 2nd Edition All Rights Reserved...
Страница 6: ......
Страница 10: ...Introduction l l Chapter 1 4...
Страница 20: ...Software Installation l l Chapter 3 14...
Страница 26: ...For Windows NT Users l l Chapter 4 20...
Страница 38: ...For DOS Users l l Chapter 7 32...
Страница 42: ...For Windows 3 x Users l l Chapter 8 36...
Страница 46: ...Chapter 9 l l RS 232 RS 422 RS 482 Programming 40...