If you are going to install multiple C114HI boards, configure one board at
a time to prevent hardware conflict. Make sure no existing devices have
the same I/O address as the CAP address, e.g. 0x180. If so, try to avoid
the conflict by doing either one of the following (a or b).
a. Short the jumper at position JP1 on the upper-left corner of C114HI.
This will force the CAP address to 0xA700.
b. Change or disable the existing board's I/O address.
ATTENTION !
For safety and to prevent C114HI from damage,
please don’t attempt to install or remove the jumper cap of JP1 until
the power of PC is off.
Step 5.
Power on the PC and enter DOS system.
Step 6.
Execute IO-IRQ.EXE included in the API-232 software driver diskette
and follow the on-line help to configure the C114HI which belongs to the
C104 family.
Step 7
.
Do software installation described in Chapter 3. After completing both
the hardware and software configurations, the board is ready for use.
Remember to connect the DB-37 to 4
¡Ñ
DB-9 cable.