4
—
Power
Input Voltage
48 VDC, redundant inputs
Input Current
1.6 A (@ 48 VDC)
Connection
Removable “6-pin” Terminal Block
Overload Current
Protection
2.5 A (@ 48 VDC)
Reverse Polarity
Protection
Present
PoE (per port)
Minimum output voltage 44 VDC
Maximum output current 350 mA (@ 48V, normal powering mode)
Inrush current
400 to 450 mA (startup mode)
Overload detection
400 mA (max.)
Output current in short
circuit condition
400 to 450 mA
Overload and short
circuit time limit
50 to 75 ms
Turn off time
500 ms
Turn off voltage
2.8V
Maximum Output Power 15.4W
Mechanical
Casing
IP30 protection, metal case
Dimensions
53.6
×
135
×
105 mm (W
×
H
×
D)
Weight 0.84
kg
Installation DIN-Rail,
Wall
Mounting
Environmental
Operating Temperature 0 to 60
°
C (32 to 140
°
F)
-40 to 75
°
C (-40 to 167
°
F) for -T models
Storage Temperature
-40 to 85
°
C (-40 to 185
°
F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
Pending: UL60950, UL 508, CSA C22.2 No. 60950,
EN60950
Hazardous Location
Pending: UL/cUL Class I, Division 2, Groups A, B,
C and D
Pending: ATEX Class I, Zone 2, EEx nC IIC
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
Shock IEC60068-2-27
Freefall IEC60068-2-32
Vibration IEC60068-2-6
WARRANTY
5 years