14
—
Grounding the SPL-24
Grounding and wire routing help limit the effects of
noise due to electromagnetic interference (EMI). Run
the right most contact of the 3-contact terminal block to
the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel.
Wiring the SPL-24’s Power Outputs
The two left-most contacts of the 3-contact terminal block connector on the
SPL-24’s top panel are used for 24 VDC output. Top and front views of one of
the terminal block connectors are shown here.
STEP 1:
Insert the negative/positive DC wires into the V-/V+
terminals.
STEP 2:
To keep the DC wires from pulling loose, use a small
flat-blade screwdriver to tighten the wire-clamp screws
on the front of the terminal block connector.
STEP 3:
Insert the plastic terminal block connector prongs into
the terminal block receptor, which is located on
SPL-24's top panel.