Страница 1: ...Splitter EDS P308 SPL 24 Hardware Installation Guide First Edition July 2006 Moxa Networking Co Ltd Tel 886 2 2910 1230 Fax 886 2 2910 1231 www moxa com support moxanet com Worldwide support moxa com The Americas P N 1802003080000 ...

Страница 2: ...mperature range of 40 to 75 C and are designed to withstand a high degree of vibration and shock The rugged hardware design makes the EDS P308 and SPL 24 perfect for ensuring that your Ethernet equipment can operate in critical industrial environments such as in hazardous locations and complies with FCC and CE standards The installation of the EDS P308 is presented on pages 3 to 10 The installatio...

Страница 3: ...st comply with fire enclosure regulation IEC 60950 EN60950 or similar regulation WARNING Safety First Be sure to disconnect the power cord before installing and or wiring your MOXA EtherDevice Switch Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ...

Страница 4: ... consumption detection and classification Industrial Grade Reliablity y Power failure port break alarm by relay output y Redundant dual DC power inputs Rugged Design y Operating temperature range from 0 to 60 C or extended operating temperature from 40 to 75 C for T models y IP30 rugged high strength case y DIN Rail or panel mounting ability Specifications of EDS P308 Technology Standards IEEE802 ...

Страница 5: ...anical Casing IP30 protection metal case Dimensions 53 6 135 105 mm W H D Weight 0 84 kg Installation DIN Rail Wall Mounting Environmental Operating Temperature 0 to 60 C 32 to 140 F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals Safety Pending UL60950 UL 508 CSA C22 2 No 60950 EN60950 Hazardous L...

Страница 6: ...ounding screw 2 Terminal block for power inputs PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 Screw holes for wall mounting kit 13 DIN Rail Kit 14 PoE port LEDs ports 1 to 4 ...

Страница 7: ...nt plate should already be fixed to the back panel of the EDS P308 when you take it out of the box If you need to reattach the DIN Rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just below the stiff metal spring STEP 2 The DIN Rail attachment unit will snap into place as shown belo...

Страница 8: ...he screws into the wall make sure the screw head and shank size are suitable by inserting the screw into one of the keyhole shaped apertures of the wall mounting plates Do not screw the screws in all the way leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws STEP 3 Once the screws are fixed in the wall insert the four screw heads through the large parts...

Страница 9: ...nal block receptor which is located on EDS s top panel ATTENTION Before connecting EDS to the DC power inputs make sure the DC power source voltage is stable EDS P308 s Alarm Contact The EDS P308 has one alarm contact located on its top panel For detailed instructions on how to connect the alarm contact power wires to the two middle contacts of the 6 contact terminal block connector see the Wiring...

Страница 10: ...t the wires to the terminal block connector and how to attach the terminal block connector to the terminal block receptor In this section we explain the meaning of the two contacts used to connect the alarm contact FAULT FAULT Top View Front View FAULT The two middle contacts of the 6 contact terminal block connector are used to detect both power faults and port faults The two wires attached to th...

Страница 11: ... On When the corresponding PORT alarm is enabled and the port s link is inactive FAULT RED Off When the corresponding PORT alarm is enabled and the port s link is active or when the corresponding PORT alarm is disabled On TP port s 10 Mbps link is active Blinking Data is being transmitted at 10 Mbps 10M GREEN Off TP Port s 10 Mbps link is inactive On TP port s 100 Mbps link is active Blinking Data...

Страница 12: ...on and classification Rugged Design y Operating temperature range from 0 to 60 C or extended operating temperature from 40 to 75 C for T models y IP30 plastic case y DIN Rail or panel mounting ability Specifications of SPL 24 Technology Standards IEEE802 3af Interface RJ45 Ports 10 100BaseT X for PoE IN and 10 100BaseT X for DATA OUT LED Indicators Power Power Input Voltage 44 to 75 VDC Output vol...

Страница 13: ...5022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 Shock IEC60068 2 27 Free Fall IEC60068 2 32 Vibration IEC60068 2 6 WARRANTY 5 years SLP 24 Panel Layout 24 VDC OUTPUT V Top View 1 2 Rear View 7 Front View 2 3 4 5 6 DATA OUT PoE IN P 1 Heat dissipation orifices 2 Terminal block for power input and grounding 3 MO...

Страница 14: ...t out of the box If you need to reattach the DIN Rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot STEP 2 The DIN Rail attachment unit will snap into place as shown below To remove the SPL 24 from the DIN Rail insert a flat blade screw driver horizontally into the DIN Rail kit under t...

Страница 15: ...wer Outputs The two left most contacts of the 3 contact terminal block connector on the SPL 24 s top panel are used for 24 VDC output Top and front views of one of the terminal block connectors are shown here STEP 1 Insert the negative positive DC wires into the V V terminals STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the f...

Страница 16: ...ve the full benefit of our products Moxa has set up on line support services to provide technical support driver updates product information and user s manual updates E mail for technical support support moxanet com Worldwide support moxa com The Americas Website for up to date product information www moxa com ...