For SNMP V3, there are two levels of privileges for different accounts to access the EDS-516A.
Admin
privilege allows access, and authorization to read and write the MIB file.
User
privilege
only allows reading the MIB file, but does not have authorization to write.
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)
Setting
Description
Factory Default
No-Auth
Use user account to access objects.
No authentication
No
MD5-
Auth
Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-
Auth
Provide authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)
Setting
Description
Factory Default
Enable
8-character data encryption key is the
minimum requirement for data encryption
(maximum of 30 characters)
No
Disable
No data encryption
No
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting
Description
Factory Default
No-Auth
Use admin account or user account to
access objects. No authentication.
No
MD5-Auth
Provides authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-Auth
Provides authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only)
Setting
Description
Factory Default
Enable
8-character data encryption key is the
minimum requirement for data encryption
(maximum of 30 characters)
No
Disable
No data encryption
No