100BaseFX Fiber Port Connection 

The concept behind the SC/ST port and cable is quite straightforward. Suppose 
you are connecting devices I and II. Contrary to electrical signals, optical signals 
do not require a circuit in order to transmit data. Consequently, one of the optical 
lines is used to transmit data from device I to device II, and the other optical line 
is used to transmit data from device II to device I, for full-duplex transmission. 

All you need to remember is to connect the Tx (transmit) port of device I to the 
Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx 
(transmit) port of device II. If you are making your own cable, we suggest 
labeling the two sides of the same line with same letter (A-to-A and B-to-B, as 
shown below).   

SC-Port 

Pinouts 

SC-Port to SC-Port Cable Wiring 

Tx

Rx

A

A

B

B

Cable Wiring

 

 

                       A

 

 

                       B

Fiber Port

SC

Connector

SC
Connecto

Tx
Rx

Fiber Port

r

Rx
Tx

 

ST-Port 
Pinouts 

Tx

Rx

A

A

B

B

Cable Wiring

 

 

                       A

ST-Port to ST-Port Cable Wiring 

 

 

                       B

Fiber Port

ST

Connector

ST
Connecto

Tx

Fiber Port

Rx

r

Rx
Tx

 

 

 

3-8 

Содержание EDS-405

Страница 1: ...Moxa EtherDevice Switch EDS 405 User s Manual Fifth Edition June 2008 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited...

Страница 2: ...tment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make...

Страница 3: ...s Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89...

Страница 4: ...ional 2 4 Chapter 3 Wiring EDS 405 3 1 Wiring Requirements 3 2 Grounding EDS 405 3 4 Wiring the Alarm Contact 3 4 Wiring the Redundant Power Inputs 3 5 Communication Connections 3 6 10 100BaseT X Ethe...

Страница 5: ...MDI X Connection 4 11 Fiber Ports 4 11 Dual Speed Functionality and Switching 4 12 Switching Filtering and Forwarding 4 12 Switching and Address Learning 4 13 Auto Negotiation and Speed Sensing 4 13...

Страница 6: ...by Moxa for industrial Ethernet switches With this plug n play ring redundancy solution your industrial automation and control applications can operate non stop The following topics are covered in thi...

Страница 7: ...promptly to emergency situations Commercial Ethernet switches need 3 to 5 minutes to recover the connection when you unplug your device from one port and then plug it into another port for field diag...

Страница 8: ...ative if any of the above items is missing or damaged Product Features EDS 405 has the following features y Plug n play ring redundancy solution recovery time 300 ms y Relay output alarm for power fai...

Страница 9: ...lt LED 8 Ring Master LED 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 10 100BaseT X Port 13 Screw hole for optional wall mounting kit 14 DIN Rail kit EDS 405 1 2 3 4 5 10M 100M P...

Страница 10: ...100M 100M RING MASTER 12 13 NOTE The appearance of EDS 405 SS SC is identical to EDS 405 MM SC 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices...

Страница 11: ...05 MM ST 1 2 3 4 5 PWR1 PWR2 FAULT 10M 100M 100M 100M RING MASTER 12 13 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Dip switches 5 Power...

Страница 12: ...2 2 Chapter 2Installing EDS 405 This chapter includes information about how to install EDS 405 The following topics are covered Mounting Dimensions DIN Rail Mounting Wall Mounting Optional...

Страница 13: ...View Front View 9 75 13 90 5 10 10 26 6 Panel Mount Kit unit mm 13 10 21 00 15 10 105 00 25 40 13 90 18 20 25 71 23 15 7 75 30 50 7 75 3 50 6 00 3 50 6 00 39 37 46 77 135 00 30 00 9 50 54 00 13 18 13...

Страница 14: ...Rail attachment plate to EDS 405 make sure the stiff metal spring is situated towards the top as shown in the figures below 1 Insert the top of the DIN Rail into the slot just below the stiff metal sp...

Страница 15: ...h wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diamet...

Страница 16: ...crew heads through the large parts of the keyhole shaped apertures and then slide Moxa EDS 405 downwards as indicated below Tighten the four screws for stability EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 F...

Страница 17: ...mation about wiring EDS 405 The following topics are covered Wiring Requirements Grounding EDS 405 Wiring the Alarm Contact Wiring the Redundant Power Inputs Communication Connections 10 100BaseT X Et...

Страница 18: ...nly be connected to the supply voltage connections and to the signal contact with the Safety Extra Low Voltages SELV in compliance with IEC950 EN60950 VDE0805 WARNING Substitution of components may im...

Страница 19: ...nd common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to...

Страница 20: ...ue to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices ATTENTION This product is intended to be mounted to a well g...

Страница 21: ...e corresponding PORT ALARM Dip Switch is set to ON is not properly connected OR 3 EDS 405 becomes the Ring Master of this Turbo Ring after the Turbo Ring was broken If none of these 3 conditions occur...

Страница 22: ...ils the other live source acts as a backup and automatically supplies all of Moxa EDS 405 s power needs Communication Connections EDS 405 MM SC ST has 3 10 100BaseT X Ethernet ports and 2 100BaseFX mu...

Страница 23: ...ugh Cable Wiring Straight Through Cable RJ45 Plug Pin 1 Switch Port RJ45 Connector RJ45 Connector Tx Tx Rx Rx Cable Wiring 3 3 6 6 1 1 2 2 NIC Port Rx Rx Tx Tx RJ45 8 pin to RJ45 8 pin Cross Over Cabl...

Страница 24: ...or full duplex transmission All you need to remember is to connect the Tx transmit port of device I to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of d...

Страница 25: ...Wiring EDS 405 ATTENTION This is a Class 1 Laser LED product Do not stare directly into the Laser LED beam 3 9...

Страница 26: ...eas some will want to make full use of EDS 405 s advanced device management functions This chapter includes the following sections Supported Ethernet Network Topologies Redundant Ring Topology Star Wi...

Страница 27: ...ets from traveling through any of the network s redundant loops In the event that one branch of this ring becomes disconnected from the rest of the network the Turbo Ring protocol automatically readju...

Страница 28: ...ASTER EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING MASTER EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING MASTER NOTE EDS 405 is a switch with plug and play ring redundancy Ports 4 and 5 are design...

Страница 29: ...then those EDS 405s whose Dip Switch 6 is set to ON will auto negotiate to determine which one will be the Ring Master If you don t enable any EDS 405 to be the Ring Master by setting Dip Switch 6 to...

Страница 30: ...port 4 or 5 of the adjacent EDS 405 When the number of EDS units in the Turbo Ring is even If there are 2N EDS units an even number in the Turbo Ring then the backup segment is one of the two segment...

Страница 31: ...LT RING MASTER EDS 2 EDS 2N 1 EDS N 2 EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING MASTER port 4 5 port 4 5 port 4 5 port 4 5 port 4 5 port 4 5 EDS N EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING...

Страница 32: ...nd the port s link is active or when the corresponding PORT alarm is disabled On When the EDS 405 is the Master of this Turbo Ring RING MASTER Green Blinking When the EDS 405 is Ring Master of the Tur...

Страница 33: ...o Ring topology and enable the Turbo Ring break alarm If the EDS 405 is the Master of this Turbo Ring and the Turbo Ring is broken the relay will form an open circuit Set to Off P1 P5 Disables the cor...

Страница 34: ...o negotiate to determine which one will be the Ring Master Upgrading the Firmware Follow the procedures given below to upgrade EDS 405 s firmware 1 Download the EDS 405 Utility zip file from www moxa...

Страница 35: ...you just downloaded 8 Locate the EDS 405 rom file and click on OPEN to start upgrading the new version of the firmware 9 After the firmware has been upgraded click on OK to refresh the information dis...

Страница 36: ...ort is required to cascade to another switch and you must swap the pin assignments by setting a dip switch to MDI X mode With auto MDI MDI X you can cascade from any port and use either a straight thr...

Страница 37: ...eries are plug and play devices so that software configuration is not required at installation or during maintenance Switching Filtering and Forwarding Each time a packet arrives at one of the switche...

Страница 38: ...ress buffer power down the unit and then power it back up Auto Negotiation and Speed Sensing All of EDS 405 s RJ45 Ethernet ports independently support auto negotiation for 10BaseT and 100BaseTX modes...

Страница 39: ...ontact One relay output with current carrying capacity of 1A 24 VDC RJ45 Ports 10 100BaseT x auto negotiation speed F H duplex mode and auto MDI MDI X connection Fiber Ports 100BaseFX ports SC ST conn...

Страница 40: ...re 0 to 60 C 32 to 140 F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals Safety UL60950 E212360 UL...