Wiring EDS-405
ATTENTION
This unit is a built-in type. When the unit is installed in another piece
of equipment, the equipment enclosing the unit must comply with fire
enclosure regulation IEC 60950/EN60950 (or similar regulation).
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring
your Moxa EtherDevice Switch.
ATTENTION
Wiring Caution!
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the maximum
current allowable for each wire size. If the current goes above the
maximum ratings, the wiring could overheat, causing serious damage
to your equipment.
You should also pay attention to the following items:
y
Use separate paths to route wiring for power and devices. If power wiring
and device wiring paths must cross, make sure the wires are perpendicular at
the intersection point.
y
NOTE
: Do not run signal or communication wiring and power wiring in the
same wire conduit. To avoid interference, wires with different signal
characteristics should be routed separately.
3-3