background image

- 7 - 

DIN-Rail Mounting (Optional) 

 

The DK-DC50131 die-cast metal kit, which 
can be bought separately, can enable easy 
and robust installation for the AWK-4131. A 
pair of DK-DC50131s is needed for DIN-rail 
mounting.  
To install the DIN-rail mounting kits, tightly 
attach the two DIN-rail mounting kits on the 
rear panel of AWK-4131 with 12 screws. (6 
screws for each kit) 

To Install 

STEP 1: 

Use the recessed button 
on the spring-loaded 
bracket to lock it in 
position. 

STEP 2: 

Insert the top of the DIN rail into the slot just 
below the upper hook of the DIN-rail 
mounting kit. Push the AWK-4131 toward 
the DIN rail until the DIN-rail attachment 
bracket snaps into place. 

 

 

To Release 

STEP 1: 

Pull out the two spring-loaded 
brackets from the bottom until 
they are fixed in the “release” 
position. 

STEP 2:

 

Pull the AWK-4131 out and upward. 

 

 

Содержание AWK-4131

Страница 1: ...a Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2016 Moxa Inc All rights reserved ...

Страница 2: ...WK 4131 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance AWK 4131 2 omni directional antennas 5 2 dBi N type male 2 4 5 GHz Wall mounting kit includes 2 supports Field installable power plug Field installable M12 8 pin male plug for Ethernet Metal cap to cover M12 male DI O connector Metal cap to cove...

Страница 3: ...pluggable transceiver with 1000BaseLH LC 30 km 0 to 60 C SFP 1GLHLC T Small form factor pluggable transceiver with 1000BaseLH LC 30 km 40 to 85 C SFP 1GLHXLC Small form factor pluggable transceiver with 1000BaseLHX LC 40 km 0 to 60 C SFP 1GLHXLC T Small form factor pluggable transceiver with 1000BaseLHX LC 40 km 40 to 85 C SFP 1GZXLC Small form factor pluggable transceiver with 1000BaseZX LC 80 km...

Страница 4: ...ale connector for Ethernet port 7 SFP port 8 RS 232 console port 9 Reset button 10 Screw holes for wall mounting 11 Waterproof vent 12 Grounding screw M8 13 Screw holes for DIN rail mounting ATTENTION Please DO NOT open or remove the vent 11 The warranty will be invalid if the seal is removed All exposed connectors including 1 2 4 9 should be tightly covered by suitable caps when they are not in u...

Страница 5: ...ector male onto the AWK 4131 device s N type connector female Caution Do not hold the rubber plate to screw the antenna on to the AWK 4131 device ATTENTION Use the antennas correctly Use 2 4 GHz antennas if the AWK 4131 operates in IEEE 802 11b g n Use the 5 GHz antennas for operations in IEEE802 11a n Make sure your antenna installation is within a safe area covered by a lightning protection or s...

Страница 6: ... the screws in all the way in to the wall leave a space of about 2 mm to allow room for sliding the wall mounting kit between the wall and the screws ATTENTION Test the screw head and shank size by inserting the screws into one of the keyhole shaped apertures of the wall mounting plates before attaching the plates to the wall STEP 3 Once the screws are fixed into the wall insert the four screw hea...

Страница 7: ...nel of AWK 4131 with 12 screws 6 screws for each kit To Install STEP 1 Use the recessed button on the spring loaded bracket to lock it in position STEP 2 Insert the top of the DIN rail into the slot just below the upper hook of the DIN rail mounting kit Push the AWK 4131 toward the DIN rail until the DIN rail attachment bracket snaps into place To Release STEP 1 Pull out the two spring loaded brac...

Страница 8: ...ith similar electrical characteristics can be bundled together Keep input wiring and output wiring separate It is strongly advised that you label wiring to all devices in the system for easy identification Grounding Moxa AWK 4131 Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surfac...

Страница 9: ...tning strikes on the AWK device In order to prevent coupling currents from nearby lightning strikes a lightning arrester should be installed as part of your antenna system Ground the device antenna as well as the arrester properly to provide maximum outdoor protection for the device Arrester Accessories SA NMNF 01 Surge arrester N type male to N type female SA NFNF 01 Surge arrester N type female ...

Страница 10: ...connecting the AWK 4131 to the DC power inputs make sure the DC power source voltage is stable ATTENTION Do not use the PoE Injector with the PoE Power over Ethernet model Instead use an IEEE802 3af or IEEE802 3at compliant PSE Power Sourcing Equipment Wiring the Digital Inputs and Relay Contact Digital Output The AWK 4131 has two sets of digital input DI1 and DI2 Each DI comprises two contacts of...

Страница 11: ...1 has 10 100 1000BaseT X Ethernet ports 8 pin shielded M12 connector with A coding The 10 100 1000BaseT X ports located on the AWK 4131 s bottom panel are used to connect to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB Switch type ports Pinouts for the 10 100 1000BaseT X M12 8 pin Port Pin Signal 1 Relay 2 3 DI1 I1 4 DI1 COM_1 5 DI2 I2 6 DI2 COM_2 7 Rese...

Страница 12: ... assignment and solder wires with 2 Then assemble and in order 3 Test the plug to ensure the quality RS 232 Connection The AWK 4131 has one RS 232 8 pin RJ45 console port located on the bottom panel Use either an RJ45 to DB9 or RJ45 to DB25 cable to connect the Moxa AWK 4131 s console port to your PC s COM port You may then use a console terminal program to access the AWK 4131 for console configur...

Страница 13: ...r is being supplied from power input 1 or 2 or PoE Off Power is not being supplied FAULT Red Blinking slow at 1 second intervals Cannot get an IP address from the DHCP server Blinking fast at 0 5 second intervals IP address conflict Off No error condition exists WLAN Green On WLAN function is in client slave mode Blinking WLAN s data communication is running in client slave mode Off WLAN is not in...

Страница 14: ...al frequency US 2 412 to 2 462 GHz 11 channels 5 18 to 5 24 GHz 4 channels EU 2 412 to 2 472 GHz 13 channels 5 18 to 5 24 GHz 4 channels JP 2 412 to 2 472 GHZ 13 channels OFDM 2 412 to 2 484 GHz 14 channels DSSS 5 18 to 5 24 GHz 4 channels for W52 Security SSID broadcast enable disable Firewall for MAC IP Protocol Port based filtering 64 bit and 128 bit WEP encryption WPA WPA2 Personal and Enterpr...

Страница 15: ...70 dBm MCS7 40 MHz 71 dBm MCS7 20 MHz 802 11g n 69 dBm MCS15 20 MHz 71 dBm MCS7 20 MHz Protocol Support General Protocols Proxy ARP DNS HTTP HTTPS IP ICMP SNTP TCP UDP RADIUS SNMP PPPoE DHCP AP only Protocols ARP BOOTP DHCP dynamic VLAN Tags for 802 1X Clients STP RSTP IEEE 802 1D w Interface Default Antennas 2 dual band omni directional antennas 5 dBi at 2 4 GHz 2 dBi at 5 GHz N type male Connect...

Страница 16: ... inputs or 48 VDC Power over Ethernet IEEE 802 3af compliant Connector M12 connector with A coding Power Consumption 12 to 48 VDC 890mA max Reverse Polarity Protection Present Standards and Certifications Safety UL 60950 1 EN 60950 1 EMC EN 301 489 1 17 FCC Part 15 Subpart B EN 55022 55024 Radio EN 300 328 EN 301 893 TELEC FCC ID SLE WAPN001 Note Check Moxa s website for the most up to date certif...

Страница 17: ...l Code Article 810 Canada Canadian Electrical Code Section 54 NOTE For installation flexibility either the A antenna or the B antenna may be selected for use Make sure the antenna connection matches the antenna configured in the AWK 4131 web interface To protect the connectors and RF module all radio ports should be terminated by either an antenna or a terminator We strongly recommend using resist...

Отзывы: