Device location
Setting
Description
Factory Default
Max. of 31 characters Specifies the location of different AWK-3131A-M12-RCC units. None
Device description
Setting
Description
Factory Default
Max. of 31 characters Use this space to record a more detailed description of the
AWK-3131A-M12-RCC
None
Device contact information
Setting
Description
Factory Default
Max. of 31 characters Provides information about whom to contact in order to resolve
problems. Use this space to record contact information of the
person responsible for maintaining this AWK-3131A-M12-RCC.
None
Network Settings
The Network Settings configuration panel allows you to modify the usual TCP/IP network parameters. An
explanation of each configuration item is given below.
IP configuration
Setting
Description
Factory Default
DHCP
The AWK-3131A-M12-RCC’s IP address will be assigned
automatically by the network’s DHCP server
Static
Static
Set up the AWK-3131A-M12-RCC’s IP address manually.
IP address
Setting
Description
Factory Default
AWK-3131A-M12-RCC’s
IP address
Identifies the AWK-3131A-M12-RCC on a TCP/IP network.
192.168.127.253
NOTE
DO NOT set the local subnet IP or the broadcast IP as the AWK-3131A-M12-RCC's IP address. For example,
192.168.127.0 and 192.168.127.255 cannot be assigned to the AWK-3131A-M12-RCC if the subnet mask is
set to 255.255.255.0.
Subnet mask
Setting
Description
Factory Default
AWK-3131A-M12-RCC’s
subnet mask
Identifies the type of network to which the
AWK-3131A-M12-RCC is connected (e.g., 255.255.0.0 for a
Class B network, or 255.255.255.0 for a Class C network).
255.255.255.0