MC12 manual
Production (Motor On/Off)
Press
to start production. The function active LED will start blinking when the unit is waiting for an
input signal. The unit is dosing if the Start LED is lighted continuously.
Test
(Material output), can only be used when unit is stopped
Test procedure to determine output of dosing system:
•
Place dosing unit horizontally leveled (water level surface).
•
Set the speed (and or) time (see settings)
•
Press
for Test
•
Weigh the material dosed during test
•
Adjust speed or time and
repeat
Test if necessary.
(Configuration 1): The unit will dose with the set speed and time.
(Configuration 2): The unit will dose for 30 seconds at the set speed
Emergency stop.
If the test is activated press stop
to cancel a test.
Alarms / Warnings
Err0 :
Motor connection failure.
Make sure the motor is connected
Check cable and connectors
Press
to acknowledge the alarm.
Keyboard lock
+
+
= Lock / Unlock,
Display shows : L.ON / L.OFF