MC12 manual
Start up
The MC12 software version is displayed shortly when the unit is switched on followed by the configuration
mode (con).
When the MC12 is set to configuration 2, the time function key
is deactivated.
When a deactivated keys is pushed the unit will give a beeping signal.
For changing the unit configuration see paragraph 7.4.
Configuration
To make the configuration available,
keep speed
and enter
pressed while switching on the main power.
The configuration number will be displayed, press
to switch between the possible configuration
and press
to acknowledge. The software version will be displayed.
Timer
Timer mode is used for injection molding with a relay input signal. When the relay contact is made, the unit
will start dosing according the number of seconds that has been set with the time function.
Relay
A relay signal can be used in case working in extruder mode. With the relay input the unit will start dosing
when the relay contact is made and will stop when the relay is interrupted.
Speed
and Timer
Speed and dosing time can be altered (time only in case of injection molding)
Speed
= rotation of dosing system in RPM, (0,1 to 200 RPM)
Timer
= time dosing system will rotate after start impulse, at input cable ( 0,1 to 999,9 sec)
Activate by pressing
or
, set the desired speed or time using
press enter
to
acknowledge
Configuration
Type of Production
Input signal
1
Injection Molding
Timer
2
Extrusion
Relay