ZD340_07d_e.doc / Apr-17
Page 20 / 50
The Start command can be assigned to any of the front keys or to or to any of the Control
Inputs, by attaching the RESET function to it (e.g. set parameter F06.052 to 1 to assign the Start
function to the ENTER key etc.). Also an automatic reset function with a timed output signal can
be used, in order to ensure automatic stepping of the cutting sequence without a remote start
signal.
The diagram below shows the switching states of outputs 2, 3 and 4 with respect to above
parameters. Output 1 must not be used with this application.
The functions and switching characteristics shown above require the following parameter
settings:
F10.101 = 1 (preset counter to Preselections)
F10.090 = 0 (Output K2 static)
F10.098 = 1 (Output K2 active when count
≤
preset)
F10.091 = 0 (Output K3 static)
F10.099 = 1 (Output K3 active when count
≤
preset)
F10.092 = x (Output K4 static or dynamic according to need)
F10.100 = 0 (Output K4 active when count
≥
preset)
Cutting length
Pre-stop
Tool width
Corr. Stop
Output K2
(High speed)
Output K3
(Run signal)
High speed
Low speed
Overshoot
Start
Output K4
(Ready to cut)