Counter B Settings
In this menu, the settings for the pulse counter (or position indicator) on channel B are defined.
This menu is only displayed when the appropriate OPERATIONAL MODE in the GENERAL MENU is
selected (e.g., "SUM A + B", "DIF A-B", "RATIO B / A", or "% DEVIA B / A").
FACTOR
Scaling factor for channel B.
For example: A setting of factor 1.23456 and 100000 input pulses will result in a value of 123456.
0,00001
Smallest value
1
Default value
99,99999
Highest value
SET VALUE
In case of a set/reset command (via keys, Control-Inputs or PC-user interface), the counter of channel A is set to
the value entered here
-99999999
Smallest value
0
Default value
+99999999
Highest value
DECIMAL POINT
This value defines the position of the decimal point.
0 NO
No decimal point
1 0000000.0
Decimal point at the specified position
2 000000.00
Decimal point at the specified position
3 00000.000
Decimal point at the specified position
4 0000.0000
Decimal point at the specified position
5 000.00000
Decimal point at the specified position
6 00.000000
Decimal point at the specified position
7 0.0000000
Decimal point at the specified position
SCALE UNITS
(display unit of measurement)
This parameter determines which unit is shown on the display. Setting the SCALE UNITS does not affect the
display value. The decimal point is set in the parameter DECIMAL POINT.
A list of possible units can be found in "COUNTER A SETTINGS - SCALE UNITS".