![Motrona touchMATRIX MX350 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/motrona/touchmatrix-mx350/touchmatrix-mx350_operating-manual_1839550026.webp)
Mx350_01a_oi_e.docx / Nov-19
page 26 / 72
Speed B Settings
In this menu, the settings for a frequency measurement / tachometer on channel B are defined.
This menu is only displayed if the corresponding OPERATIONAL MODE is selected in the GENERAL
MENU. (e.g., "SUM A + B", "DIF A-B", "RATIO B / A", or "% DEVIA B / A")
DISPLAY VALUE
Desired value, which should be displayed at the setting of BASE FREQUENCY.
1
Smallest value
1000
Default value
99999999
Highest value
BASE FREQUENCY (HZ)
Reference frequency for the desired DISPLAY VALUE.
1
Smallest value
100
Default value
500000
Highest value
DECIMAL POINT
This value defines the position of the decimal point.
0 NO
No decimal point
1 0000000.0
Decimal point at the specified position
2 000000.00
Decimal point at the specified position
3 00000.000
Decimal point at the specified position
4 0000.0000
Decimal point at the specified position
5 000.00000
Decimal point at the specified position
6 00.000000
Decimal point at the specified position
7 0.0000000
Decimal point at the specified position
SAMPLING TIME (S)
The configured value corresponds to the minimum measurement time. The Parameter is used as a filter in case
of irregular frequencies. This parameter directly affects the response time of the unit.
0.005
Shortest Sampling time
0.1
Default value
9.999
Longest Sampling time