Dz260_05a_oi_e.doc / Dez-16
Page 27 / 40
7.2.9.
Switching –Menu
These parameters are not relevant for model DZ266.
Indications | f | mean that only the absolute value of the frequency is considered. With all other
indications, frequencies are categorically signed (+ with forward and - with reverse)
Switching -Menu
(Switching characteristics of relays/outputs)
Code
Setting Range
Default
Pulse Time 1
Rel.1: Duration of timed output, sec. (0=static)
„F8“
0 ... 9.99
0
Pulse Time 2
Rel.2: Duration of timed output, sec. (0=static)
„F9“
0 ... 9.99
0
Pulse Time 3
Rel.3: Duration of timed output, sec. (0=static)
„G0“
0 ... 9.99
0
Hysteresis 1
Rel.1: Switching Hysteresis (engineering units)
„G1“
0 ... 99999.9
0
Hysteresis 2
Rel.2: Switching Hysteresis (engineering units)
„G2“
0 ... 99999.9
0
Hysteresis 3
Rel.3: Switching Hysteresis (engineering units)
„G3“
0 ... 99999.9
0
Preselect Mode 1
(switching operation for relay 1/output 1)
„G4“
0..9
0
0
|f| >= |Preselection| (catch*)
1
|f| <= |Preselection| with start-up-delay (catch*)
2
|f| == |Preselection| with start-up-delay (catch*)
3
Standstill (f=0) after expiration of standstill time
4
f >= Preselection (catch*)
(also suitable for signalization of forward direction)
5
f <= Preselection (catch*)
(also suitable for signalization of reverse direction)
6
f == Preselection (catch*)
7
Relay/output signals "forward" when a positive frequency (f > 0)
is detected. This information disappears upon detection of
"standstill"
8
Relay/output signals "reverse" when a negative frequency (f < 0)
is detected. This information disappears upon detection of
"standstill"
9
f > (Presel Hysteresis) or f < (Preselection – Hysteresis)
with start-up suppression and latch *)
The parameter Preselection forms the center, the hysteresis
specifies the area around.
Preselect Mode 2
(switching operation for relay 2/output 2)
see Preselection Mode 1
„G5“
0..8
0
Preselect Mode 3
(switching operation for relay 3/output 3)
see Preselection Mode 1
„G6“
0..8
0
*)
The corresponding relay/output can be used with catch operation, when a catch function has been
assigned to it under parameter „Lock Relay“.