Dz260_05a_oi_e.doc / Dez-16
Page 23 / 40
7.2.6.
Command-Menu
Command-Menu
(assignment of functions)
Code
Setting Range
Default
Key Up Func.
Supplementary command function of the UP key
„D7“
0..9
0
0
no function
1
Activation of a serial data transmission
2
Force programmed relay/output states / freeze (a)(c)
3
Frequency simulation according to parameter "Set Value"
4
Freeze actual input frequency
5
Remote start-up-delay function (a)
6
Release lock of relay 1 (a)
7
Release lock of relay 2 (a)
8
Release lock of relay 3 (a)
9
Release lock of all relays 1-3 (a)
Key Down Func.
Supplementary command function of the DOWN key
(see UP)
„D8“
0..9
0
Key Enter Func.
Supplementary command function of the ENTER key
(see UP)
„D9“
0..9
0
Input 1 Config.
Switching characteristics of input „Control1“
„E0“
0..3
0
0
Static low
1
Static High
2
Dynamic, rising edge
3
Dynamic, falling edge
Input 1 Func.
Control function of input „Control1“
„E1“
0..12
0
0
no function
1
Activation of a serial data transmission
2
Force programmed relay/output states / Freeze (a)(c)
3
Frequency simulation according to parameter "Set Value"
4
Freeze actual input frequency
5
Remote start-up-delay function (a)
6
Release lock of relay 1/transistor output 1 (a)
7
Release lock of relay 2/transistor output 2 (a)
8
Release lock of relay 3/transistor output 3 (a)
9
Release lock of all relays 1-3/output 1-3
(a)
10
Interlock for parameter access via keypad (b)
11
Total keypad interlock (b)
12
Command monitor for remote motion enable signal
Input 2 Config.
(see Input 1 Config.)
„E2“
0..3
0
Input 2 Func.
(see Input 1 Func.)
„E3“
0..12
0
(a) these parameters are not relevant for model DZ266.
(b) see section
6.2
(c) see section
9.3
(d) see section
9.4