Dx350_06d_oi_e.docx / Jul-20
page 39 / 67
Continuation „PRESELECTION 1 MENU“:
10 RESULT>= PRES->VALUE
Auto reset to “SET VALUE”: (only in mode TIMER or COUNTER)
Display value is greater or equal PRESELECTION 1, the display value is set to the
respective “SET VALUE”.
If the BATCH MODE is active, the batch counter increments or decrements, when
the display value is set to the respective “SET VALUE” and when the
corresponding source of supply MEASUREM. RESULT, COUNTER A or COUNTER B
was selected.
11 ERROR SET
Error message for device errors
HYSTERESIS 1
This parameter defines the switching hysteresis of the switch-off point for preselection 1
0
No switching hysteresis
…
9999
Switching hysteresis of 99999
PULSE TIME 1 (S)
Duration of output pulse for the switching condition of preselection 1
0.000
No output pulse (static signal)
…
60.000
Pulse duration of 60 seconds
OUTPUT TARGET 1
Assignment of an output or relay for the switching condition of preselection 1.
If more than one switching condition is assigned to one output / relay, the output is set when at least one switching
condition is true
0 NO
No assignment
1 CTRL OUT 1
Switching condition assigned to “Ctrl. Out 1”
2 CTRL OUT 2
Switching condition assigned to “Ctrl. Out 2”
3 CTRL OUT 3
Switching condition assigned to “Ctrl. Out 3”
4 CTRL OUT 4
Switching condition assigned to “Ctrl. Out 4”
5 RELAY 1
Switching condition assigned to “Rel. 1”
6 RELAY 2
Switching condition assigned to “Rel. 2”
OUTPUT POLARITY 1
Polarity for the switching condition of preselection 1
0 ACTIVE HIGH
Switching condition is true
Active „HIGH“
1 ACTIVE LOW
Switching condition is true
Active „LOW“
OUTPUT LOCK 1
Latch for the switching condition of preselection 1
0 NO
No latch for preselection
1 YES
Latch for preselection (command LOCK RELEASE will clear latch)